Number of MRs in Which the Signal Strength Difference Between the Serving Cell and the Neighbor Cell Is Greater Than the Neighbor Cell Interference Level Threshold N

Measurement Counter

S364:CELL_SCELL_NCELL_LEV_GT_THRES1_MR_NUM

S365:CELL_SCELL_NCELL_LEV_GT_THRES2_MR_NUM

S366:CELL_SCELL_NCELL_LEV_GT_THRES3_MR_NUM

S367:CELL_SCELL_NCELL_LEV_GT_THRES4_MR_NUM

S368:CELL_SCELL_NCELL_LEV_GT_THRES5_MR_NUM

S369:CELL_SCELL_NCELL_LEV_GT_THRES6_MR_NUM

S370:CELL_SCELL_NCELL_LEV_GT_THRES7_MR_NUM

Description

The MS measures the information of the serving cell and neighbor cells, and sends the information to the BTS in an MR. The BTS then sends the information to the BSC in an MR. This measurement provides the number of times that the signal strength difference between the serving cell and each neighbor cell contained in the MRs is between two successive Neighbor Cell Interference Level Thresholds subtracted by 64. This measurement is used to show the mapping between the receive level of the serving cell and the receive level of neighbor cells, and provide a basis for formulating the frequency planning scheme.

Unit

Integer number or integer.

Measurement Point

After receiving a valid MR from the MS, the BSC compares the receive level of the serving cell with that of each neighbor cell. A specific counter is measured in the following situations: N ranges from 1 to 7.

The counter S364:CELL_SCELL_NCELL_LEV_GT_THRES1_MR_NUM is incremented by one when the following formula is met: neighbor cell receive level + Neighbor Cell Interference Level Threshold 1 ≤ serving cell receive level + 64 .

The counter S365:CELL_SCELL_NCELL_LEV_GT_THRES2_MR_NUM is incremented by one when the following formula is met: neighbor cell receive level + Neighbor Cell Interference Level Threshold 2 ≤ serving cell receive level + 64 .

The counter S366:CELL_SCELL_NCELL_LEV_GT_THRES3_MR_NUM is incremented by one when the following formula is met: neighbor cell receive level + Neighbor Cell Interference Level Threshold 3 ≤ serving cell receive level + 64 .

The counter S367:CELL_SCELL_NCELL_LEV_GT_THRES4_MR_NUM is incremented by one when the following formula is met: neighbor cell receive level + Neighbor Cell Interference Level Threshold 4 ≤ serving cell receive level + 64 .

The counter S368:CELL_SCELL_NCELL_LEV_GT_THRES5_MR_NUM is incremented by one when the following formula is met: neighbor cell receive level + Neighbor Cell Interference Level Threshold 5 ≤ serving cell receive level + 64.

The counter S369:CELL_SCELL_NCELL_LEV_GT_THRES6_MR_NUM is incremented by one when the following formula is met: neighbor cell receive level + Neighbor Cell Interference Level Threshold 6 ≤ serving cell receive level + 64 .

The counter S370:CELL_SCELL_NCELL_LEV_GT_THRES7_MR_NUM is incremented by one when the following formula is met: serving cell receive level + 64 ≥ neighbor cell receive level + Neighbor Cell Interference Level Threshold 7.

The measurement object of this counter is configurable. If the measurement object is not configured, this counter is not measured.

Formula

This is an original counter without involving any formula.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.