Number of MRs on Competitive Cell (Receive Level Rank N)

Measurement Counter

S386:CELL_NCELL_LEVEL_0

S387:CELL_NCELL_LEVEL_1

S388:CELL_NCELL_LEVEL_2

S389:CELL_NCELL_LEVEL_3

S340:CELL_NCELL_LEVEL_4

S341:CELL_NCELL_LEVEL_5

S342:CELL_NCELL_LEVEL_6

S343:CELL_NCELL_LEVEL_7

Description

This measurement provides the number of the measurements of MR on competitive cell that the signal strength is in receive level N. N ranges from 0 to 7, mapping to [0-10], (25-30], (30-35], (35-40], (40-45], (45-50], and (50-63] respectively.
NOTE:

The round bracket indicates that the adjacent value is exclusive while the square bracket indicates that the adjacent value is inclusive.

Unit

Integer number or integer.

Measurement Point

On receiving a valid MR from the MS, the BSC compares the signal strength of current serving cell with the signal strength of the neighbor cell. If the signal strength of the neighbor cell is within the range of N, the corresponding counter is incremented by one.

NOTE:

The measurement does not consider whether the neighbor cell is a competitive cell or not (the cell from another telecom operator). The BSC will measure the corresponding counters based on the signal strength of all neighbor cells provided by the MS. The measurement objects of the competitive cell are configured on the M2000.

Formula

This is an original counter without involving any formula.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.