Downlink Quality during Radio Link Failure (TCHF)

Measurement Counter

S4337D:TRX_FR_DROP_DL_QLTY

Description

After receiving a valid MR or pre-processed MR, the BSC takes statistics of some parameter values based on the requirements. The statistics can help users better understand the network performance. The measurement provides the accumulated downlink quality value reported by the MRs during the radio link failure on the TCHF. This counter is used to calculate the counter AS3337D: TRX_FR_DROP_DL_QLTY_AVR.

Unit

Integer number or integer.

Measurement Point

In the granularity period, this counter is incremented by the downlink quality value in the last valid MR or pre-processed MR before the radio link failure occurs on the TCHF.

Formula

This is an original counter without involving any formula.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.