Average Frame Erasion Rate of the FR in the Customized MR

Measurement Counter

S4562: TRX_EXT_ERASE_FRM_AVR_RATE

Description

This measurement provides the average frame erasion rate of the FR in the customized MR in a granularity period.

Frame erasion rate reflects the bit error rate of the frames received by the DSP on the TRX of the BTS.

Unit

None.

Measurement Point

In the granularity period, the counter is calculated as follows.

Formula

Average Frame Erasion Rate of the FR in the Customized MR = [Total Frame Erasion Rate of the FR in the Customized MR]/[Number of the Measurements of the Frame Erasion Rate of the FR in the Customized MR]