S4565: TRX_EXT_TCHH_ERASE_FRAME_AVG_RATE
This measurement provides the average frame erasion rate of the FR in the customized MR in a granularity period.
Frame erasion rate reflects the bit error rate of the frames received by the DSP on the TRX of the BTS.
None.
In the granularity period, the counter is calculated as follows.
Average Frame Erasion Rate of the HR in the Customized MR =
[Total Frame Erasion Rate of the HR in the Customized MR]/[Number of the Measurements of the Frame Erasion Rate of the HR in the Customized MR]