Average Downlink BER Probability Variance

Measurement Counter

S4809B:CELL_DL_SIG_CVBEP_AVR

Description

During a granularity period, every time the BSC receives an EMR or pre-processed EMR from the BTS, the BSC accumulates the CV_BEP in the EMR. At the end of the granularity period, the value of this counter is the result of dividing the accumulative value of CV_BEP by the number of EMRs.

Unit

None.

Measurement Point

In the granularity period, the counter is calculated as follows.

Formula

Average Downlink BER Probability Variance = [Downlink BER Probability Variance]/([Number of EMRs on the TCHF] + [Number of EMRs on the TCHH])