In-Service Duration of MTP3 Link

Measurement Counter

TL6001:MTP3_LNK_INSERVICE_DUR

Description

This measurement provides the duration of the MTP3 link in service.

Unit

Integer number or integer.

Measurement Point

The measurement point is on the BSC side, as shown in the figure.



Formula

In-Service Duration of MTP3 Link=({GP} x {60}) - [Out-of-Service Duration of MTP3 Link]