ZCH970E:BSCRPT_HO_REQ_TA
This measurement provides the number of outgoing inter-cell handover requests of all the cells controlled by a BSC due to timing advance, including outgoing internal inter-cell handover requests and outgoing external inter-cell handover requests.
The BSC uses the handover algorithm to decide whether a handover is required based on the measurement reports submitted by the MS. If a handover is required, and if the source cell (current cell) and the target cell are two different cells controlled by one BSC, the BSC initiates an internal inter-cell handover. If the handover cause value is timing advance, the BSC measures the number of outgoing internal inter-cell handover requests due to timing advance in the source cell. If the source cell (current cell) and the target cell are two different cells controlled by different BSCs, the BSC initiates an external inter-cell handover. If the handover cause value is timing advance, the BSC measures the number of outgoing external inter-cell handover requests due to timing advance in the source cell.
Integer number or integer.
This counter is measured according to the following formula when the measurement period ends. For details on the measurement point, see "Measurement Point" of each counter in the formula.
Attempted Handovers per BSC (Timing Advance) = Outgoing Internal Inter-Cell Handover Requests (Timing Advance) + Outgoing External Inter-Cell Handover Requests (Timing Advance)