ZS4186B:TRX_FR_DL_RX_QLTY_6_RATIO
This measurement provides the ratio of MRs, of which the receive quality rank is 6, on downlink TCHF per BSC.
%.
This counter is measured according to the formula below when the measurement period ends. For details on the measurement point, see "Measurement Point" of each counter in the formula.
Ratio of MRs on Downlink TCHF (Receive Quality Rank 6) per BSC=
[Number of MRs on Downlink TCHF (Mean Receive Quality Rank 6) per BSC] x {100}
/
([Number of MRs on Downlink TCHF (Mean Receive Quality Rank 0) per BSC] +
[Number of MRs on Downlink TCHF (Mean Receive Quality Rank 1) per BSC] +
[Number of MRs on Downlink TCHF (Mean Receive Quality Rank 2) per BSC] +
[Number of MRs on Downlink TCHF (Mean Receive Quality Rank 3) per BSC] +
[Number of MRs on Downlink TCHF (Mean Receive Quality Rank 4) per BSC] +
[Number of MRs on Downlink TCHF (Mean Receive Quality Rank 5) per BSC] +
[Number of MRs on Downlink TCHF (Mean Receive Quality Rank 6) per BSC] +
[Number of MRs on Downlink TCHF (Mean Receive Quality Rank 7) per BSC])