ZTA03447:BSCRPT_GCC_INTERBSC_INTOCELL_HO_SUCC
In the inter-BSC VGCS TCH handover procedure, upon receiving a HANDOVER REQUEST message from the MSC, the target BSC assigns new channels to the MS. After the MS successfully accesses the target cell, the BSC sends a HANDOVER COMPLETE message to the MSC. This measurement provides the number of times that the BSC sends a HANDOVER COMPLETE message to the MSC.
Integer number or integer.
At the end of each granularity period, this counter is measured by using the following formula. For details, see Successful Incoming Inter-BSC Inter-Cell VGCS TCH Handovers.
Successful Incoming Inter-BSC Inter-Cell VGCS TCH Handovers per BSC = Successful Incoming Inter-BSC Inter-Cell VGCS TCH Handovers
(That is, the total of the counter Successful Incoming Inter-BSC Inter-Cell VGCS TCH Handovers in each cell of the BSC.)