Call Drops on TCH per BSC (Other Causes)

Measurement Counter

ZTM333:BSCRPT_TOTAL_CELL_CALL_DROPS_OTHER

Description

This measurement provides the number of call drops on the TCHs per BSC due to other causes, such as no measurement reports from the MS for a long time, equipment failure, and resource check within the BSC.

Unit

Integer number or integer.

Measurement Point

This counter is measured according to the following formula when the measurement period ends. For details on the measurement point, see "Measurement Point" of each counter in the formula.

Formula

Call Drops on TCH per BSC (Other Causes) =

[ Call Drops due to No MRs from MS for a Long Time (TCHF) (Signaling Channel)]+

[ Call Drops due to No MRs from MS for a Long Time (TCHF) (Traffic Channel)]+

[ Call Drops due to No MRs from MS for a Long Time (TCHH) (Signaling Channel)]+

[ Call Drops due to No MRs from MS for a Long Time (TCHH) (Traffic Channel)]+

[ Call Drops due to Equipment Failure (TCHF) (Signaling Channel)]+

[ Call Drops due to Equipment Failure (TCHF) (Traffic Channel)]+

[ Call Drops due to Equipment Failure (TCHH) (Signaling Channel)]+

[ Call Drops due to Equipment Failure (TCHH) (Traffic Channel)]+

[ Call Drops due to Resource Check (TCHF) (Signaling Channel)]+

[ Call Drops due to Resource Check (TCHH) (Signaling Channel)]+

[ Call Drops due to Resource Check (TCHF) (Traffic Channel)]+

[ Call Drops due to Resource Check (TCHH) (Traffic Channel)]


Huawei Proprietary and Confidential