ID | Name | Meaning |
---|---|---|
1 | PCU No. | The number of the PCU whose links are disrupted |
2 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
Y=>Refer to the handling suggestions for clearing E1/T1 alarms.
N=>Go to 2.
Y => Go to 3.
N => Reset the interface board. If the alarm persists, contact the Huawei Customer Service Center.
Y => Go to 4.
N => Modify the configuration data in the PCU or in the BSC to ensure that the PCU configuration data is consistent with the BSC configuration data.
Y => The alarm handling is complete.
N => Go to 5.
Y => The alarm is cleared. The alarm handling is complete.
N => Please contact Huawei Customer Service Center.