ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Subrack No. |
2 | Slot No. | Slot No. |
3 | Cpu No. | CPU No. |
4 | Port No. | The number of the port |
5 | Site No. | The IDs of all sites whose OMLs are on the faulty E1/T1. If BTS are cascade connected,a maximum of 4 sites are shown.Only Abis E1/T1 alarm has this parameter. |
6 | Site Name | The Names of all sites whose OMLs are on the faulty E1/T1. If BTS are cascade connected,a maximum of 4 sites are shown.Only Abis E1/T1 alarm has this parameter. |
7 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
Y => If the board is an Ater interface board, Go to b. If the board is an Abis interface board, Go to d.
N => The board is of another type. Go to g.
20081 Loss of E1/T1 Signals (LOS)
20082 Loss of E1/T1 Frames (LOF)
20084 E1/T1 Alarm Indication Signal (AIS)
Y => One of these alarms is reported. Go to c.
N => None of these alarms is reported. Go to 2.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
4714 E1/T1 Local Alarm or other E1 local alarms
4718 AIS Alarm or other AIS alarms
Y => One of these alarms is reported. Go to f.
N => None of these alarms is reported. Contact Huawei Customer Service Center.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Y => Rectify the fault according to the relevant alarm help. The alarm handling is complete.
N => Go to 2.
Y => If the board is an Ater interface board, Go to b. If the board is an Abis interface board, Go to e.
N => The board is of another type. Go to i.
Y => The alarm is cleared. The peer GEIUT is faulty. Go to c.
N => The alarm is not cleared. The transmission equipment or transmission link between the local and peer GEIUTs is faulty. Contact the transmission engineers. The alarm handling is complete.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to d.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Y => The alarm is cleared. The E1 lightning protection board or the TMU in the BTS is faulty. Go to g.
N => The alarm is not cleared. The transmission equipment or transmission link between the BSC and the BTS is faulty. Contact the transmission engineers. The alarm handling is complete.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to h.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Y => The alarm is cleared. The interface board of the peer NE is faulty. Contact the maintenance engineers of the peer NE. The alarm handling is complete.
N => The alarm is not cleared. The transmission equipment or transmission link between the BSC and the peer NE is faulty. Contact the transmission engineers. The alarm handling is complete.