ALM-12302 LAPD Link Abnormal Alarm

Description

This alarm is reported when the LAPD link is broken.

Attribute

Alarm ID Alarm Severity Alarm Type
12302 Critical Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

67:BTS3900B module

3 Board No.

Number of the fault board

0:BTS3900B module

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

29:BTS3900B;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

13 Carrier No.

Carrier No.

0:Carrier0

1:Carrier1

Impact on the System

When the alarm is generated, the services carried by the base station are disrupted.

System Actions

The BSC and the BTS try to perform the link setup automatically when the alarm is generated.

Possible Causes

  • The transmission link between the BSC and the BTS is faulty.
  • The data configuration is incorrect.
  • The BTS fails to detect the TSs.

Procedure

  1. Check for other related alarms.

    Check whether the BSC also reports the Ethenet link alarm. If this alarm is reported, handle the alarm according to handling suggestions in ALM-12304 Ethernet Port Status Abnormal Alarm, and then check whether the alarm is cleared.

    If the preceding alarm is not reported. Go to procedure 2.

  2. Check the data configuration.

    Check whether the IP addresses of the BSC and the BTS3900B module are correct.

    Y=> The configuration is correct. Go to procedure 3.

    N => The configuration is incorrect. Modify the configuration, and then go to procedure [3].

  3. Check the transmission link.

    Check whether the transport network between the BTS and the BSC is normal.

    Y => Remove and then install the cables to ensure that the connections are proper. Go to procedure 4.

    N => Rectify the connection fault, and then go to procedure [4].

  4. Check whether the alarm is cleared.

    Y => The alarm is cleared. End the alarm handling.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.