ALM-12810 BTS Configuration Conflict Alarm

Description

This alarm is reported when the configuration of the BSC is inconsistent with the actual installation, for example, the frequency set is wrongly configured, or the configured frequency is inconsistent with the band type of the BTS3900E.

Attribute

Alarm ID Alarm Severity Alarm Type
12810 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

107:BTS3900E

3 Board No.

Number of the fault board

0-3: BTS3900E

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:Abnormal power control parameter configuration

1:Inconsistent channel configuration and system messages

3:Invalid value of the data configuration attributes

4:Configured board power exceeding the board transmit capability

5:Abnormal configuration of the board RAN sharing attributes

6:Inconsistent frequency type configuration

7:Configured frequency exceeding the board working range

8:Board frequency band exceeding working band

252:Configured board type inconsistent with the actual requirement

253:SFP0 Port Inconsistency with the actual requirement

254:SFP1 Port Inconsistency with the actual requirement

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

30:BTS3900E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

13 Cause of the Fault

Cause of the fault

0:The configuration of the power control parameters is incorrect.

1:The channel configuration and the system information are inconsistent.

2:The board type and the configuration are inconsistent.

3:The value of data configuration attribute is invalid.

4:The power configuration of the board exceeds the TX capability of the board.

5:The configuration of the RAN sharing of the boards is abnormal.

6:The configuration of the frequency type is inconsistent.

7:The frequency configuration exceeds the operating range of the board.

8:The configuration of the frequency band exceeds the operating range of the board.

252:Configured board type inconsistent with the actual requirement

253:SFP0 Port Inconsistency with the actual requirement

254:SFP1 Port Inconsistency with the actual requirement

Impact on the System

When the alarm is generated, the BTS3900E module related to such configuration may fail to work properly.

System Actions

None.

Possible Causes

  • The transmission between the BSC and the BTS is faulty.
  • The BSC Abis interface board is faulty.
  • The BTS3900E module hardware is faulty.
  • The configuration of combined cabinets is inconsistent with the actual connection.
  • The connections between combined cabinets are broken.
  • The frequency configured is inconsistent with the band type of the BTS3900E module.

Procedure

  1. Check the data configuration.

    Log in to the BSC and check the data configuration as follows:

    1. Check Channel Attributes.
    2. Check CCCH Parameters in the System Information [/#2003].
    3. Check Channel Type Configuration.
    4. Check Frequency Configuration.
    5. Check the Configuration Information on the LMT .
    6. Check the Assigned Frequency [/#2120]

      Y => The data configuration is correct. Go to procedure 2.

      N => The data configuration is incorrect. Go to procedure 2.

    7. Check whether the configured frequencies are consistent with the actual band type of the BTS3900E module.

      Log in to the BSC, and check whether the configured frequencies are consistent with the actual band type of the BTS3900E.

      Y=> The configured frequencies are consistent with the actual frequency band type of the BTS3900E module, yet the alarm is not cleared. Contact Huawei Customer Service Center.

      N=> Go to step h.

    8. Check whether the number of networking levels is consistent with the actual configuration.

      Y=> Check whether the ALM-12812 SFP Link Fault exists. If the alarm exists, check the handling suggestions of the ALM-12812 SFP Link Fault for troubleshooting.

      N => Send the configuration to the BTS again and then go to procedure [2].

    9. Modify Data Configuration.
  2. Reset the BTS.

    Reset the Site in Level 4 on the BSC or the LMT. Check whether the alarm is cleared.

    Y=> The alarm is cleared. End the alarm handling.

    N=> The alarm is not cleared. Go to procedure 3.

  3. Replace the BTS3900E module.

    Replace the BTS3900E Module that is faulty. Check whether the alarm is cleared.

    Y=> The alarm is cleared. End the alarm handling.

    N=> The alarm is not cleared. Contact Huawei Customer Service Center.