ALM-12820 Board Maintenance Link Abnormal Alarm

Description

This alarm is reported when communication between BTS3900E modules is failed.

Attribute

Alarm ID Alarm Severity Alarm Type
12820 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

107:BTS3900E

3 Board No.

Number of the fault board

0-3: BTS3900E

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

30:BTS3900E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When the alarm is generated, the BTS3900E fails to work properly.

System Actions

The system automatically shuts down the PA.

Possible Causes

  • The BTS3900E module is out of position, manually reset, or powered off.
  • The BTS3900E module is damaged.

Procedure

  1. Check whether ALM-12810 BTS Configuration Conflict Alarm exists on the BSC LMT.

    Y => The alarm exists. Rectify the fault accoding to the handling suggestions of this alarm.

    N => Go to procedure 2.

  2. Check whether the BTS3900E module is manually reset or powered down. Check for the BTS3900E module with abnormal communication through the alarm identification information.

    Y=> The BTS3900E module is manually reset or powered down. No manual handling is required. End the alarm handing.

    N=> Go to procedure 3.

  3. Check whether the optical or electrical module is broken. If it is broken, alarms such as ALM-12810 BTS Configuration Conflict Alarm are generated. Rectify the faults according to the related suggestions and check whether the alarm is cleared.

    Y => The alarm is cleared. End the alarm handling.

    N => The alarm is not cleared. Go to procedure 4.

  4. Replace the BTS3900E Module, and check whether the alarm is cleared.

    Y => The alarm is cleared. End the alarm handling.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.