ID | Name | Meaning |
---|---|---|
1 | DPCGROUP | DPCGROUP of the reset circuit that is not configured |
2 | CicNum | Numbers of Circuit identification code (CIC) of the reset circuits those are not configured |
3 | CIC | Circuit identification code (CIC) of the reset circuit that is not configured |
4 | OSP | Original signaling point (OSP) of the subrack where the reset circuit is located |
5 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
The circuit status of the BSC and that of the MSC are inconsistent and thus the services cannot be processed.
20081 Loss of E1/T1 Signals (LOS)
20082 Loss of E1/T1 Frames (LOF)
Y => The alarm handling is complete.
N => Go to 2.
Y => Go to b.
N => Reconfigure the data.
Y => Reinsert the GEIUA/GOIUA.
N => Go to c.
Y => Contact the maintenance engineers.
N => Go to d.
Y => The alarm handling is complete.