ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Subrack No. |
2 | Slot No. | Slot No. |
3 | Cpu No. | CPU No. |
4 | Port No. | The number of the port |
5 | Bit Error Type | 0=NO ERR,1=CRC,2=FAS,3=CRC and FAS,4=Code Violation,5=Code Violation and CRC,6=Code Violation and FAS,7=Code Violation and CRC and FAS |
6 | Site No. | The IDs of all sites whose OMLs are on the faulty E1/T1. If BTS are cascade connected,a maximum of 4 sites are shown.Only Abis E1/T1 alarm has this parameter. |
7 | Site Name | The Names of all sites whose OMLs are on the faulty E1/T1. If BTS are cascade connected,a maximum of 4 sites are shown.Only Abis E1/T1 alarm has this parameter. |
8 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
Y => If the value of Bit Error Type includes Code Violation, Go to b.
N => The value of Bit Error Type doesn't include Code Violation, Go to 2.
Y => The link codes are configured consistently. Go to 2.
N => The link codes are configured inconsistently. Go to c.
Once being set, the link code of the port of the BSC cannot be changed. Therefore, if the link code of the port of the BSC is different from the link code of the port of the peer NE, you can only change the link code of the port of the peer NE.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
Y => If the E1/T1 cable is loosened, Go to b. If the E1/T1 cable is damaged, Go to c.
N => The E1/T1 cable is properly connected. Go to 3.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to c.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 3.
Y => The clock status is normal. Go to 4.
N => The clock status is not normal. Go to b.
Y => The clock status is normal. Go to 4.
N => The clock status is not normal. Go to c.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to d.
Y => The status is normal. Go to 4.
N => The status is not normal. Go to e.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 4.
Y => The BSC subrack is properly grounded. Go to 5.
N => The BSC subrack is improperly grounded. Go to b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Y => If the peer NE is the GMPS/GEPS/GTCS, Go to b. If the peer NE is the BTS, Go to c.
N => The peer NE is not the GMPS/GEPS/GTCS or the BTS. Go to f.
20081 Loss of E1/T1 Signals (LOS)
20082 Loss of E1/T1 Frames (LOF)
20084 E1/T1 Alarm Indication Signal (AIS)
Y => One of these alarms is reported. Rectify the fault according to the relevant alarm help. The alarm handling is complete.
N => None of these alarms is reported. Contact Huawei Customer Service Center.
4714 E1/T1 Local Alarm or other E1 local alarms
4718 AIS Alarm or other AIS alarms
Y => One of these alarms is reported. Go to e.
N => None of these alarms is reported. Contact Huawei Customer Service Center.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Y => The alarm is cleared. The peer NE is faulty. Contact the maintenance engineers of the peer NE. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.