ID | Name | Meaning |
---|---|---|
1 | Subrack No. | Subrack No. |
2 | Slot No. | Slot No. |
3 | Cpu No. | CPU No. |
4 | Tributary Unit No. | 0 - 62(for E1 mode), 0 - 83(for T1 mode). |
5 | Site No. | The IDs of all sites whose OMLs are on the faulty E1/T1. If BTS are cascade connected,a maximum of 4 sites are shown.Only Abis E1/T1 alarm has this parameter. |
6 | Site Name | The Names of all sites whose OMLs are on the faulty E1/T1. If BTS are cascade connected,a maximum of 4 sites are shown.Only Abis E1/T1 alarm has this parameter. |
7 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
If the APS function is enabled on the interface board, no handling is performed.
If the APS function is disabled on the interface board, the handling varies with the operation modes of the board.
Y => The frame formats are consistent. Go to 2.
N => The frame formats are inconsistent. Go to b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
Y => The optical cable between the BSC and the peer equipment is correctly connected. Go to c.
N => The optical cable between the BSC and the peer equipment is incorrectly connected. Go to b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to c.
Y => If the optical connector is loosened or detached, Go to d. If the optical connector is dirty, Go to e. If the optical cable is damaged, Go to f.
N => If the optical connector is correctly connected, Go to 3.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to e.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to f.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 3.
Y => The alarm is cleared. Both the BSC interface board and the optical cable connected to the BSC interface board are normal. Reconnect the optical port, and Go to 4.
N => The alarm is not cleared. The BSC interface board or the optical cable connected to the BSC interface board is faulty. Go to b.
Y => The alarm is cleared. The optical cable connected to the BSC interface board is faulty. Go to c.
N => The alarm is not cleared. The BSC interface board is faulty. Go to d.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 4.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to e.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 4.
Y => If the peer NE is the GMPS/GEPS/GTCS, Go to b. If the peer NE is the BTS, Go to d.
N => The peer NE is not the GMPS/GEPS/GTCS or the BTS. Go to f.
20222 Loss of Signals on the Optical Port (RLOS)
20223 Loss of Received Signal Frames on the Optical Port (RLOF)
20228 Multiplex Section Alarm Indication Signal (MAIS)
20248 Loss of Tributary Signals (LOS)
20249 Tributary Alarm Indication Signal (AIS)
20250 Loss of Tributary Frames (LOF)
Y => One of these alarms is reported. Go to c.
N => None of these alarms is reported. Contact Huawei Customer Service Center.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
4714 E1/T1 Local Alarm or other associated alarms
4718 AIS Alarm or other AIS alarms
Y => One of these alarms is reported. Go to f.
N => None of these alarms is reported. Contact Huawei Customer Service Center.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Y => The peer NE reports the alarms related to the transmission. Rectify the fault according to the relevant alarm help. The alarm handling is complete.
N => The peer NE does not report the alarms related to the transmission.Contact Huawei Customer Service Center.