ALM-2118 TRX Software Running Abnormal Alarm

Description

A TRX reports this alarm when detecting a failure in its processor.

Attribute

Alarm ID Alarm Severity Alarm Type
2118 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:TRX

3 Board No.

Number of the fault board

Value range: 0-71

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

3: BTS30

5: BTS312

10: BTS3012A

11: BTS3006A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

All the services on the TRX will be interrupted upon occurrence of this alarm.

System Actions

  • The TMU will reset the TRX upon occurrence of this alarm. It will reset the TRX in 30 minutes if it has reset it 50 times.
  • If the TRX carries a BCCH, the system will start BCCH mutual-assistance.

Possible Causes

  • TRX software failure.
  • FPGA logic failure.
  • DSP software failure or DSP mailbox communication failure.

Procedure

  1. Check the Related Alarms

    On the LMT, check whether the ALM-2166 TRX Clock Prompt Alarm is reported.

    Y=> Handle ALM-2166 TRX Clock Prompt Alarm. Check whether the alarm is cleared.

    N=> Go to step 2.

  2. Check the Software Version

    Check whether the software version is correct.

    Y=> Correct. You can infer that the TRX hardware is faulty. Go to step 3.

    N=> Incorrect. Reload the correct software and activate it. If the alarm is cleared, the alarm handling is complete. Otherwise, go to step [3].

  3. Replace the TRX

    Replace the TRX and check whether the alarm is cleared.

    Y=> The alarm is cleared. The alarm handling is complete.

    N=> The alarm is Not cleared. Contact the Huawei Customer Service Center.


Huawei Proprietary and Confidential