ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 135:TRX |
3 | Board No. | Number of the fault board Value range: 0-71 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 3: BTS30 5: BTS312 10: BTS3012A 11: BTS3006A |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
On the LMT, check whether the ALM-2166 TRX Clock Prompt Alarm is reported.
Y=> Handle ALM-2166 TRX Clock Prompt Alarm. Check whether the alarm is cleared.
N=> Go to step 2.
Check whether the software version is correct.
Y=> Correct. You can infer that the TRX hardware is faulty. Go to step 3.
N=> Incorrect. Reload the correct software and activate it. If the alarm is cleared, the alarm handling is complete. Otherwise, go to step [3].
Replace the TRX and check whether the alarm is cleared.
Y=> The alarm is cleared. The alarm handling is complete.
N=> The alarm is Not cleared. Contact the Huawei Customer Service Center.