ID | Name | Meaning |
---|---|---|
1 | PHY Link No. | Number of the link Each link has only one number on the GXPUM CPU |
2 | Subrack No. | Number of the subrack where the board is located |
3 | Slot No. | Number of the slot where the GXPUM is located |
4 | CPU No. | Number of the CPU where the GXPUM is located |
5 | Network Indicator | 0=International,1=International Standby,2=National,3=National Standby |
6 | Dest Signaling Point Code | Code of the DSP in the signaling network, which is specified when configuring data of the signaling point |
7 | Source Signaling Point Code | Code of the signaling point in the signaling network, which is specified when configuring data of the signaling point |
8 | Signaling Link Code | Only code of the signaling link in the link set that is a set of links |
9 | Cause | The values of alarm causes are as follows: 0x02: MTP3 sends the stop command. 0x08: The MTP2 reports that the location is impossible during the IAC. 0x09: MTP2 receives the abnormal BSN. 0x0A: MTP2 receives the abnormal FIB. 0x0C: MTP2 receives SIO from the destination point. 0x0D: MTP2 receives SIN from the destination point. 0x0E: MTP2 receives the critical SIE from the destination point. 0x0F: MTP2 receives SIOS from the destination point. 0x12: The error rate of the signal rate is high. 0x13: T1 (45 seconds) expires. 0x14: T6 (5 seconds) expires. The signaling links are congested for a long time. 0x15: T7 (1.5 seconds) expires. The messages are delayed for a long time. 0x16: T2 (30 seconds) expires. 0x17: T3 (1.3 seconds) expires. 0x19: The error rate is high. 0x1B: MTP3 sends a stop message during the LSC. 0x30: Receive the COO signal from the destination point. 0x31: The test of the signaling links fails. 0x32: The signaling links are deactivated. 0x33: Software on layer 2 is unavailable. 0x34: The communication with the management module stops. 0x35: Commands on layer 2 and layer 3 have no responses. 0x36: The physical links are faulty for a long time. 0x37: The link switchover expires. 0x38: Software data on layer2 are reconfigured. 0x40: The local management is prohibited, and the links are unavailable. 0x41: The remote management is prohibited, and the links are unavailable. 0x42: The remote processor is faulty. 0x44: Set data in the table again. The system restarts and reports alarms. 0xFF: Other reasons. |
10 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
The MTP3 will periodically initiates signaling link re-establishment. The link resumes normal operation once the cause of the link unavailability is cleared.
Y => Go to 3.
N => Go to 2.
Y => Add a signaling link.
N => Go to 3.
Y => Refer to the relative handling suggestion.
N => If the 21205 Board Fault alarm is cleared or does not exist, but the alarm cannot be cleared, Go to 4.
Y => Activate the corresponding link. The alarm handling is complete.
N => Please contact Huawei Customer Service Center.