ALM-2170 DBUS Alarm

Description

The alarm is triggered when the data bus (DBUS) on the shelf is not available.

Attribute

Alarm ID Alarm Severity Alarm Type
2170 Minor Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:TRX

3 Board No.

Number of the fault board

0:TRX 0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

3: BTS30

5: BTS312

10: BTS3012A

11: BTS3006A

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The services on some or all TRXs will be interrupted upon occurrence of this alarm.

System Actions

None.

Possible Causes

  • The E1 transmission link is faulty.
  • The DBUS on the shelf is not available.
  • The TMU is faulty.

Procedure

  1. Check whether a correlated parent alarm occurs.

    Y=> Clear the parent alarm according to the corresponding handling suggestions. Check whether the alarm is cleared.

    N=> Go to step 2.

    Correlated parent alarm

    ALM-2214 E1 Local Alarm

    The parent alarm and the child alarm have the same Site No. and Module No. in the alarm location information.

    If the E1 transmission link is faulty, an E1 local alarm occurs, and a parent alarm occurs accordingly.

  2. Check whether there is any correlated alarm

    Check whether ALM-2214 E1 Local Alarm exists in the LMT. If yes, handle ALM-2214 E1 Local Alarm according to the corresponding handling suggestions. Check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 3.

    If no such alarms are reported, go to Step [3].

  3. Check whether only one end of the E1 cable is grounded

    Check whether the DIP switches on the TMU are correctly set. If no, modify the setting to ensure that only one end of the E1 cable is grounded. Check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 3.

    If the DIP switches on the TMU are correctly set, go to Step [3].

  4. Replace the TMU

    Replace the TMU and check whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Huawei Customer Service Center.