ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 135:MFU |
3 | Board No. | Number of the fault board 0:MFU 0 1:MFU 1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255:None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 7: BTS3001C-108/BTS3001C-116 8: BTS3001C-204 |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
All services supported by the local BTS3001C are interrupted upon the occurrence of this alarm.
Check whether the ALM-3152 E1 Local alarm is reported on the LMT.
Y=> Handle the ALM-3152 E1 Local alarm according to the corresponding instructions to check whether it is cleared. The alarm is cleared, Alarm handling is completed. The alarm is not cleared, Go to Step 2.
N=> Go to Step2.
Loopback transmission: If the BTS3001C adopts E1 transmission mode, then perform loopback test for the E1 cable from the BSC or the senior BTS. If the BTS3001C adopts optical transmission mode, perform loopback test for the optical fiber from the BSC or the senior BTS and test the timeslot corresponding to the LAPD to see whether there are any error codes.
Y=> There is a fault on the transmission line. Repair the transmission line. The alarm handling ends.
N=>Go to Step 3.
Check whether the physical connection of the faulty site is consistent with the port configuration.
Y=>The physical connection of the site is consistent with the port configuration, Go to Step 4.
N=>The physical connection of the site is not consistent with the port configuration. In this case, modify the data configuration and change the value consistent with the physical connection . The alarm handling ends.
Perform level-4 reset on the BTS3001C through the local maintenance system. Check whether the alarm is cleared.
Y=> The alarm handling ends.
N=>Contact Huawei Customer Service Center to replace the faulty hardware.