ALM-3072 Radio Link alarm

Description

This alarm is triggered when the BTS3001C detects the failure of the radio link continuously. The radio link abnormity includes two cases: for all non-main BCCH carriers, the radio link fault occurs to the odd timeslots or even timeslots 20 times continuously, or there is no uplink message. For main-BCCH carriers, there are not any traffic over them for long (24 hours).

Attribute

Alarm ID Alarm Severity Alarm Type
3072 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:MFU

3 Board No.

Number of the fault board

0:MFU 0

1:MFU 1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:warning for abnormal channel activation. It indicates that the channel types or channel states between BTS and BSC are not consistent.

1:warning for abnormal channel release. It indicates that the proportion of abnormal channel release exceeds the relevant alarm threshold.

2:Warning for no traffic on primary BCCH. It indicates that there is no traffic detected on the primary BCCH within the specified time.

3:warning for power level imbalance between uplink and downlink. It indicates that the uplink power level and the downlink power level deviate from each other greatly.

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

7: BTS3001C-108/BTS3001C-116

8: BTS3001C-204

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

All services supported by the local BTS3001C may be interrupted upon the occurence of this alarm. Meanwhile, MFU(s) is maybe reset.

System Actions

None.

Possible Causes

  • Data configuration error.
  • Inner container hardware of the BTS fails.

Procedure

  1. Check the traffic statistics

    Check whether there is no traffic over the faulty TRX for long.

    Y=>Go to Step 2.

    N=>Go to Step 5.

  2. Check whether there are any correlated alarms

    Check whether there is a ALM-3420 Low Forward Power alarm on the LMT.

    Y=> There is aALM-3420 Low Forward Power alarm. The inner container hardware is faulty. Contact Huawei Customer Service Center for solutions.

    N=> There is no ALM-3420 Low Forward Power alarm. Go to Step 3.

  3. Measure the output power

    Measure the output power at the BTS3001C antenna port with a power meter to see whether it complies with the data configuration.

    Y=> Resume the original connection between the antenna port and the feeder. Go to Step 4.

    N=>The inner container hardware may be faulty. Contact Huawei Customer Service Center.

  4. Dialing test

    Lock the faulty frequency with an MS and make a call test to see whether the test call is successful.

    Y=>Go to Step 5.

    N=>The inner container hardware may be faulty. Contact Huawei Customer Service Center.

  5. Reset the MFU

    Reset the MFU through the LMT to see whether this alarm is cleared.

    Y=> The alarm handling ends.

    N=>Contact Huawei Customer Service Center to replace the faulty inner container hardware.


Huawei Proprietary and Confidential