ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 135:MFU |
3 | Board No. | Number of the fault board 0:MFU 0 1:MFU 1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0:warning for abnormal channel activation. It indicates that the channel types or channel states between BTS and BSC are not consistent. 1:warning for abnormal channel release. It indicates that the proportion of abnormal channel release exceeds the relevant alarm threshold. 2:Warning for no traffic on primary BCCH. It indicates that there is no traffic detected on the primary BCCH within the specified time. 3:warning for power level imbalance between uplink and downlink. It indicates that the uplink power level and the downlink power level deviate from each other greatly. |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board or module is located 7: BTS3001C-108/BTS3001C-116 8: BTS3001C-204 |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
All services supported by the local BTS3001C may be interrupted upon the occurence of this alarm. Meanwhile, MFU(s) is maybe reset.
Check whether there is no traffic over the faulty TRX for long.
Y=>Go to Step 2.
N=>Go to Step 5.
Check whether there is a ALM-3420 Low Forward Power alarm on the LMT.
Y=> There is aALM-3420 Low Forward Power alarm. The inner container hardware is faulty. Contact Huawei Customer Service Center for solutions.
N=> There is no ALM-3420 Low Forward Power alarm. Go to Step 3.
Measure the output power at the BTS3001C antenna port with a power meter to see whether it complies with the data configuration.
Y=> Resume the original connection between the antenna port and the feeder. Go to Step 4.
N=>The inner container hardware may be faulty. Contact Huawei Customer Service Center.
Lock the faulty frequency with an MS and make a call test to see whether the test call is successful.
Y=>Go to Step 5.
N=>The inner container hardware may be faulty. Contact Huawei Customer Service Center.
Reset the MFU through the LMT to see whether this alarm is cleared.
Y=> The alarm handling ends.
N=>Contact Huawei Customer Service Center to replace the faulty inner container hardware.