ALM-3120 Frame Or TS Number alarm

Description

This alarm is triggered when the received frame number or TS number is abnormal because the MFU clock or hardware fails.

Attribute

Alarm ID Alarm Severity Alarm Type
3120 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

135:MFU

3 Board No.

Number of the fault board

0:MFU 0

1:MFU 1

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

7: BTS3001C-108/BTS3001C-116

8: BTS3001C-204

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

When this alarm occurs, all the services on the current BTS3001C are interrupted.

System Actions

None.

Possible Causes

  • The MMU 13M clock fails.
  • The MFU clock circuit fails.
  • The frame number receiving chip in the MFU fails.

Procedure

  1. Check whether there is any correlated alarm
    1. Check whether the LMT has also reported a ALM-3172 MMU Clock alarm.

      Y=> Handle the alarm according to the related handling suggestions to check whether it is cleared. The alarm is cleared, Alarm handling is completed. The alarm is not cleared, Go to Step 2.

      N=> The alarm has not been cleared. Go to step b.

    2. Check whether the LMT has also reported a ALM-3438 Clock alarm.

      Y=>Handle the alarm according to the related handling suggestions.The alarm is cleared, Alarm handling is completed. The alarm is not cleared, Go to Step 2.

      N=>Go to step 2.

  2. Reset MMU

    Reset the MMU through the LMT. Check whether the alarm is cleared.

    Y=>The alarm handling ends.

    N=>The possible cause is that the hardware in the BTS3001C is faulty.Contact Huawei Customer Service Center.