ALM-3208 Site Reset alarm

Description

This alarm is reported when the BTS is powered on or reset.

Attribute

Alarm ID Alarm Severity Alarm Type
3208 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

129:MMU

3 Board No.

Number of the fault board

0:MMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board or module is located

7: BTS3001C-108/BTS3001C-116

8: BTS3001C-204

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

The system will clear this alarm three minutes after it occurs.

Possible Causes

The BTS3001C is reset.

Procedure

  1. Check whether BTS3001C is reset manually

    Check whether BTS3001C is reset manually

    Y=>The system will clear the alarm automatically in three minutes. It is not necessary to handle it. The alarm handling ends.

    N=>Go to step 2.

  2. Check whether the BTS3001C power fails

    Check whether the BTS3001C resets because of power failure.

    Y=>The possible cause is that the BTS3001C power supply is abnormal. Handle the alarm according to the corresponding instructions of ALM-3200 BTS3001C Power Abnormal alarm. The alarm has been cleared and the alarm handling ends.

    N=>Go to step 3.

  3. Check whether the BTS3001C transmission is abnormal

    Check whether the BTS3001C is reset because of long-term (over 15 minutes) interruption of the transmission.

    Y=>The possible cause is that the BTS3001C transmission is abnormal. The alarm has been cleared and the alarm handling ends.

    N=>The possible cause is that the hardware in the BTS3001C is faulty.Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.