ID | Name | Meaning |
---|---|---|
1 | NSEI | ID of the NSE where the alarm is generated |
2 | Alarm Attribute | 0=Normal, Alarms period are longer than the Transient Threshold. 1=Transient Count, The times and the period of the alarms whose periods are shorter than the Transient Threshold are summed up. If the sum result is longer than the Alarm Occurrence Period Threshold or Alarm Occurrence Times Threshold, an alarm so called Transient Count Alarm is triggered. Because Transient Count Alarm is based on accumulative result, the recovery of the alarm may occur at least one Summing Cycle later. The Summing Cycle can be query by MML "LST STATSLDWIN". |
Y => Go to 2.
N => Configure BC service state to be available.
Y => Go to 3.
N => Configure NSVC service state to be available.
Y=> The alarm is cleared.
N => On the LMT of the BSC, Configure NSVC to make the configuration of the NSE and NSVC on the BSC be the same as the configuration on the SGSN.
Y => Go to 5.
N => On the LMT of the BSC, reconfigure the BC to make the configuration of the BC identifier on the BSC be the same as the configuration on the SGSN.
Y=> The alarm handling is complete.