ALM-4128 RX/TX PLL out of Lock

Description

This alarm is reported when the send phase-lock loop and receive phase-lock loop in the Carrier Module cannot output the working frequency needed.

Attribute

Alarm ID Alarm Severity Alarm Type
4128 Warning Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The services may not be influenced for the send phase-lock loop and receive phase-lock loop both have backups.

System Actions

Check if the alarm is cleared every certain period of time.

Possible Causes

Faulty hardware

Procedure

  1. Check other relevant alarms.

    Check if the LMT reports ALM-4184 TRX Clock Critical Alarm.

    Y=> if exist, Handle the alarm. Check if the alarm is cleared.

    N=> if not, Go to Step 2.

  2. Check if ALM-4184 TRX Clock Critical Alarm is reported.

    Check if the LMT reports ALM-4184 TRX Clock Critical Alarm.

    Y=> if exist, Handle the alarm. Check if the alarm is cleared.

    N=> if not, Go to Step 3.

  3. Reset the BTS.

    Four-level reset or power-off reset the BTS on the LMT.

    (Power-off reset is recommended.) Then check if the alarm is cleared.

    Y=> The alarm is cleared. Alarm Handling is completed.

    N=> The alarm is not cleared. Go to Step 4.

  4. Plug out and in the main control module and the DTRU.

    Power off the BTS, plug out and in and secure the contacts between the modules and the backplane. Power on again and see if the alarm is cleared.

    Y=> The alarm is cleared. Alarm Handling is completed.

    N=> The alarm is not cleared. The faulty may lie in faulty DTRU or main control module hardware. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential