Description

This alarm is generated when the reverse power from the power output of the TRX is too high. This alarm is generated when the cables concerning the power output port of the TRX (TX1, TX2, TCOM) are not properly connected. This alarm is generated for the Carrier Module if the VSWR exceeds the major VSWR alarm threshold of the Carrier Module. This alarm is generated when the antenna jumper is not connected to the antenna port of the Carrier Module.

Attribute

Alarm ID Alarm Severity Alarm Type
4144 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

0:TRX VSWR alarm in TX/RX Channel A;

1:TRX VSWR alarm in TX/RX Channel B;

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

Once the alarm is generated, the service carried by the TRX is totally interrupted.

System Actions

The TRX shuts down the power amplifier automatically. For the main BCCH TRX, the mutual TRX aid is enabled.

Possible Causes

  • The cable is not securely connected to the power output port of the TRX.
  • The cable is not securely connected to the power input port of the RF front-end unit.
  • The cable between the power output port of the TRX and the power input port of the RF front-end unit is damaged.
  • The RF front-end unit is faulty.
  • The DTRU is faulty.

Procedure

  1. According to the alarm information, check the connections between the modules and the cable connectors.
    1. Check whether the connections between the modules and the cable connectors are loose.

      Y => A connection is loose. Go to step b.

      N => All the connections are secure. Go to 2.

    2. Tighten the loose connectors.
    3. Reset the TRX. Check whether the alarm is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm is not cleared. Go to 2.

  2. Check the RF connections and site configuration.
    1. Check whether the RF connections and the site configuration are matched.

      Y => The connections of RF cables, jumpers, and RF modules are matched with the configuration of the logical transmit mode. Go to 3.

      N => The connections of RF cables, jumpers, and RF modules are not matched with the configuration of the logical transmit mode. Go to step b.

    2. Adjust the RF connections according to site configuration.
    3. Reset the TRX. Check whether the alarm is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm is not cleared. Go to 3.

  3. Replace the TRX. Check whether the alarm is cleared.

    Y => The alarm is cleared. The alarm handling is complete.

    N => The alarm is not cleared. Go to 4.

  4. Check the VSWR of the related components.
    1. Measure the VSWR by using the related instrument (for example, the SiteMaster) at the antenna port of the duplexer. Check whether the fault occurs on the jumper, surge protector, feeder, TMA, or the antenna.

      Y => A component is faulty. Go to step b.

      N => All the components are normal. Contact Huawei Customer Service Center.

    2. Replace the faulty component.
    3. Reset the TRX. Check whether the alarm is cleared.

      Y => The alarm is cleared. The alarm handling is complete.

      N => The alarm is not cleared. Contact Huawei Customer Service Center.