ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 65:DTRU/GTRU/DDRM 88:DRRU 92:DRFU 96:MRRU 100:MRFU 101:GRFU 102:GRRU 151:QTRU |
3 | Board No. | Number of the fault board |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0:TRX VSWR alarm in TX/RX Channel A; 1:TRX VSWR alarm in TX/RX Channel B; |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Once the alarm is generated, the service carried by the TRX is totally interrupted.
The TRX shuts down the power amplifier automatically. For the main BCCH TRX, the mutual TRX aid is enabled.
Y => A connection is loose. Go to step b.
N => All the connections are secure. Go to 2.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
Y => The connections of RF cables, jumpers, and RF modules are matched with the configuration of the logical transmit mode. Go to 3.
N => The connections of RF cables, jumpers, and RF modules are not matched with the configuration of the logical transmit mode. Go to step b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 3.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 4.
Y => A component is faulty. Go to step b.
N => All the components are normal. Contact Huawei Customer Service Center.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.