ALM-4200 Abnormal Fan Speed

Description

This alarm is reported when the fan speed exceeds 25% of the object speed.

Attribute

Alarm ID Alarm Severity Alarm Type
4200 Minor Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DDRM

3 Board No.

Number of the fault board

0-53:DDRM

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

13:BTS3006C;

14:BTS3002E;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The heat dissipation capability of the DTRU has gone down.

System Actions

None.

Possible Causes

The fan is aging or has obstacles inside.

Procedure

  1. Check whether there are obstacles inside the fan. Clear the obstacles and check whether the alarm is cleared.

    Check if the extension DTMU or the slave DTMU has been installed or powered on.

    Y=> The alarm is cleared. Alarm handling is completed.

    N=> The alarm is not cleared. Go to Step 2.

  2. Replace the fan and check whether the alarm is cleared

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared. Go to Step 3.

  3. Replace the DTRU and check whether the alarm is cleared

    Y=>The alarm is cleared. Alarm handling is completed.

    N=>The alarm is not cleared. Please contact Huawei Customer Service Center.