ALM-4208 Cable Connection of the TRX Output Port Alarm

Description

The alarm is reported when the cables of the TRX output port are not connected or connected incorrectly.

Attribute

Alarm ID Alarm Severity Alarm Type
4208 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

65:DTRU/GTRU/DDRM

88:DRRU

92:DRFU

96:MRRU

100:MRFU

101:GRFU

102:GRRU

151:QTRU

3 Board No.

Number of the fault board

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The services carried on the TRX are completely disrupted when the alarm is generated.

System Actions

The power amplifier (PA) of the TRX is automatically shut down.

Possible Causes

  • The cables of the configured TRX output port are not connected properly.
  • The transmit mode is inconsistent with the connection of the cables.
  • The TRX hardware is faulty.

Procedure

  1. Check whether the transmit mode is consistent with the connection of the cables.
    1. Check whether the transmit mode is consistent with the connection of the cables.

      Y => The transmission mode is consistent with the connection of the cables. Go to procedure 2.

      N => The transmission mode is inconsistent with the connection of the cables. Go to step b.

    2. Reconnect the cables of the TRX output port.

      After reconnecting the cables, check whether the alarm is cleared.

      Y => The alarm is cleared. No further action is required.

      N => The alarm is not cleared. Go to procedure 2.

  2. Check whether the cables and the connectors are connected properly.
    1. Check whether the cables and the connectors are connected properly.

      Y => The cables and the connectors are connected properly. Go to procedure 3.

      N => The cables and the connectors are connected improperly. Go to step b.

    2. Reconnect the cables and the connectors.

      After the reconnection, check whether the alarm is cleared.

      Y => The alarm is cleared. No further action is required.

      N => The alarm is not cleared. Go to procedure 3.

  3. Reset the TRX.

    After resetting the TRX, check whether the alarm is cleared.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Go to procedure 4.

  4. Replace the TRX.

    After replacing the TRX, check whether the alarm is cleared.

    Y => The alarm is cleared. No further action is required.

    N => The alarm is not cleared. Contact Huawei Customer Service Center.