ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 64:DTMU/DOMU 87:GTMU |
3 | Board No. | Number of the fault board 0-5:DTMU/GTMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number Sub No. 0:no response to queries about DSP version of TRX of cell 0 Sub No. 1:no response to queries about DSP version of TRX of cell 1 Sub No. 2:no response to queries about DSP version of TRX of cell 2 Sub No. 3:no response to queries about DSP version of TRX of cell 3 Sub No. 4:no response to queries about DSP version of TRX of cell 4 Sub No. 5:no response to queries about DSP version of TRX of cell 5 |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
When the alarm is generated, TRXs of the cell related to the alarm cannot enter the aging state.
Observe whether the alarm is cleared after the resetting.
Y=> The alarm is cleared. Alarm handling is complete.
N=> The alarm is not cleared. Go to step 2.
Observe whether the alarm is cleared after the replacement.
Y=> The alarm is cleared. Alarm handling is complete.
N=> The alarm is not cleared. Please contact Huawei Customer Service Center.