ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 64:DTMU/DOMU 87:GTMU |
3 | Board No. | Number of the fault board 0-5:DTMU/GTMU |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm Sub-Category Number Sub No. 0: Writing or reading the Flash error. Sub No. 1: SD539 chip initialized improperly. Sub No. 2: 32.768 MHz clock alarm. Sub No. 3: FPGA alarm. Sub No. 4: 2.048 MHz clock alarm. Sub No. 7: E1 port 0 circuit abnormal. Sub No. 8: E1 port 1 circuit abnormal. Sub No. 9: E1 port 2 circuit abnormal. Sub No. 10: E1 port 3 circuit abnormal. Sub No. 11: E1 port 4 circuit abnormal. Sub No. 12: E1 port 5 circuit abnormal. Sub No. 13: E1 port 6 circuit abnormal. Sub No. 14: E1 port 7 circuit abnormal. Sub No. 16: E1 chip 1 initialized improperly. Sub No. 17: E1 chip 2 initialized improperly. Sub No. 18: SFP-A rate mismatched. Sub No. 19: SFP-B rate mismatched. Sub No. 20: Combined cabinets transceiver internal phase-locked loop unlocked. Sub No. 21: Combined cabinets reference clock phase-locked loop unlocked. Sub No. 22: EPLD load failure. Sub No. 23: 13 MHz system clock failed to be calibrated. Sub No. 24: 32.768 MHz clock lost. Sub No. 25: 125 MHz clock lost. Sub No. 26: 50 MHz clock lost. Sub No. 27: 2 MHz clock lost. Sub No. 28: TRAN FPGA clock lost. Sub No. 29: BRI FPGA clock lost. Sub No. 30: 12 VA power alarm. Sub No. 31: 12 VB power alarm. Sub No. 32: 5 V CANBUS power alarm. Sub No. 33: 1.2 V power alarm. Sub No. 34: Heat board faulty. Sub No. 35:Serdes chip 0 fault. Sub No. 36:Serdes chip 1 fault. |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; 17:DBS3900 GSM; 18:BTS3900 GSM; 19:BTS3900A GSM; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Y=>The alarm is cleared. Alarm handling is complete.
N=>Go to Step 2.
Y=>The alarm is cleared. Alarm handling is complete.
N=>The alarm is not cleared. Please contact Huawei Customer Service Center.