ALM-4798 Main Control Module Voltage Alarm

Description

The internal power supply of the DTMU master controlling module is abnormal.

Attribute

Alarm ID Alarm Severity Alarm Type
4798 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

64:DTMU/DOMU

87:GTMU

3 Board No.

Number of the fault board

0-5:DTMU/GTMU

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

17:DBS3900 GSM;

18:BTS3900 GSM;

19:BTS3900A GSM;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

The master control module runs abnormally when the alarm is reported.

System Actions

None.

Possible Causes

  • The input -48V power supply is not within the range.
  • The hardware of the master clock module is faulty.

Procedure

  1. Check if the input -48V power supply is within range of -40V~-60V.

    Y=> The alarm is not cleared. Go to Step 2.

    N=> Check the external power supply. Alarm Handling is completed.

  2. Replace the DTMU

    Replace the DTMU and see if the alarm has been cleared.

    Y=> The alarm is cleared. Alarm handling is completed.

    N=> The alarm is not cleared. Please contact Huawei Customer Service Center.


Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.