ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. C7:P-CDU C9:D-CDU |
3 | Board No. | Number of the fault board 0:CDU 0 1:CDU 1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 255: None |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 3:BTS30; 5:BTS312; 10:BTS3012A; 11:BTS3006A; 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Check the connections between the jumper and the duplexer, between the jumper and the feeder, between the jumper and the surge protector, and between the jumper and the antenna.
Y => All the connections are good. Go to step c.
N => A connection is not secured. Go to step b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to step c.
Y => There is water leakage. Go to step d.
N => There is no water leakage. Go to 2.
Y => The alarm is cleared. Reset the TRX. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
Y => The VSWR is abnormal. Go to step a.
N => The VSWR is normal. Go to 3.
Y => The alarm is cleared. Reset the TRX. The alarm handling is complete.
N => The alarm is not cleared. Go to 3.
Y => The alarm is cleared. Reset the TRX. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.