ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 66:DDPU(EDU) |
3 | Board No. | Number of the fault board 0:EDU 0 1:EDU 1 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0: EDU port 0 1: EDU port 1 |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 3:BTS30; 5:BTS312; 10:BTS3012A; 11:BTS3006A; 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
When this alarm is generated, the TRX connected with the faulty sub-route of the EDU has no output power and therefore cannot carry services. The services can be restored only when this alarm is cleared and the TRX is reset manually.
When this alarm is generated, the system automatically shuts down the power amplifier of the corresponding TRX. If the TRX aiding function is enabled on the BCCH TRX, the system starts the TRX aiding function.
Check the connections between the jumper and the duplexer, between the jumper and the feeder, between the jumper and the surge protector, and between the jumper and the antenna.
Y => All the connections are good. Go to step c.
N => A connection is not secured. Go to step b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to step c.
Y => There is water leakage. Go to step d.
N => There is no water leakage. Go to 2.
Y => The alarm is cleared. Reset the TRX. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
Y => The VSWR is abnormal. Go to step a.
N => The VSWR is normal. Go to 3.
Y => The alarm is cleared. Reset the TRX. The alarm handling is complete.
N => The alarm is not cleared. Go to 3.
Y => The alarm is cleared. Reset the TRX. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.