ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 66:DUP Unit |
3 | Board No. | Number of the fault board Value range:0-35 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0: FCLK abnormal 1: OBCLK abnormal |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Reset the DUP Unit on the LMT and check if the alarm is cleared.
Y=> The alarm is cleared. Alarm handling is completed.
N=> Go to Step 2.
Check if the cable at the COM port of the DUP Unit is destroyed or the terminal is loose. Replace the cable or fasten the terminal and see if the alarm is cleared.
Y=> The alarm is cleared. Alarm handling is completed.
N=> Go to Step 3.
Replace the DDPU Unit and check if the alarm is cleared.
Y=> The alarm is cleared. Alarm handling is completed.
N=> Go to Step 4.
Replace the main controlling unit and see if the alarm is cleared.
Y=> The alarm is cleared. Alarm handling is completed.
N=> The alarm is not cleared. Please contact Huawei Customer Service Center.