ID | Name | Meaning |
---|---|---|
1 | Site No. | Number of the site where the faulty board or module is located Value range: 0-2047 |
2 | Board Type | Number of the type which the faulty board belongs to. 66:DUP Unit |
3 | Board No. | Number of the fault board Value range:0-35 |
4 | PassNo | Number of the passage where the faulty board is located. |
5 | SubLink No. | Alarm sub-category number 0: Path A standing wave alarm 1: Path B standing wave alarm |
6 | Cell Index | Index of the cell where the board or module is located 0-2047: Cell index of the faulty cell in the data configuration 65535: None |
7 | Site Type | Type of the site where the faulty board is located. 12:BTS3012; 13:BTS3006C; 14:BTS3002E; 15:BTS3012AE; 16:BTS3012 II; |
8 | RackNo | Number of the rack where the faulty board is located. |
9 | BoxNo | Number of the subrack where the faulty board is located. |
10 | SlotNo | Number of the slot where the faulty board is located. |
11 | Site Name | Site Name |
12 | Alarm Attribute | Alarm Character 0:Normal 1:Transient Count |
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 2.
Y => All the connections are good. Go to 3.
N => A connection is not secured. Go to step b.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to step c.
Y => There is water leakage. Go to step d.
N => There is no water leakage. Go to 3.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 3.
Replace the duplexer. Check whether the alarm is cleared.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Go to 4.
Y => The alarm is cleared. The alarm handling is complete.
N => The alarm is not cleared. Contact Huawei Customer Service Center.
Locate the fault by using the preceding method. For example, if the measured VSWR of the jumper at the antenna port of the duplexer is abnormal, you can infer that the VSWR alarm is caused by the duplexer. The faults of other components can be located in the same way.
Reset the TRX to restore the services.