ALM-8048 TES Communication Alarm

Description

This alarm is triggered when the communication link between the TES and the TMU fails.

Attribute

Alarm ID Alarm Severity Alarm Type
8048 Major Fault

Parameters

ID Name Meaning
1 Site No.

Number of the site where the faulty board or module is located

Value range: 0-2047

2 Board Type

Number of the type which the faulty board belongs to.

68:DASU(TEU)

3 Board No.

Number of the fault board

0:TEU 0

4 PassNo

Number of the passage where the faulty board is located.

5 SubLink No.

Alarm sub-category number

255:None

6 Cell Index

Index of the cell where the board or module is located

0-2047: Cell index of the faulty cell in the data configuration

65535: None

7 Site Type

Type of the site where the faulty board is located.

3:BTS30;

5:BTS312;

10:BTS3012A;

11:BTS3006A;

12:BTS3012;

13:BTS3006C;

14:BTS3002E;

15:BTS3012AE;

16:BTS3012 II;

8 RackNo

Number of the rack where the faulty board is located.

9 BoxNo

Number of the subrack where the faulty board is located.

10 SlotNo

Number of the slot where the faulty board is located.

11 Site Name

Site Name

12 Alarm Attribute

Alarm Character

0:Normal

1:Transient Count

Impact on the System

None.

System Actions

None.

Possible Causes

  • The physical link for communication between the TMU and the TES is faulty.
  • The TES is not is in power-on state.
  • The TES has not been installed.

Procedure

  1. Check whether the TES has been installed

    Check whether the TES has been installed. Install it if not. View whether the alarm is cleared.

    Y=> The alarm handling ends.

    N=> Go to Step 2.

  2. Check whether the TES is in power-on state

    Check whether the TES power indicator is normal. Remove the TES to check it, and then reinsert it into the original position if in well-condition. This action will make services interrupted.

    Y=> The alarm handling ends.

    N=> Go to Step 3.

  3. Replace the TES

    Replace the TES with a proper one. View whether the alarm is cleared after the new board becomes in normal operation. This action will make services interrupted.

    Y=> The alarm handling ends.

    N=> Huawei Customer Service Center.

    NOTE:

    The TES supports hot-line plug.


Huawei Proprietary and Confidential