This describes the principles of configuring the built-in PCU devices. When the built-in PCU is used, the BSC must be configured with the related boards to process the PS services, and the configuration must follow the related principles.
The BSC should be configured with the GDPUP to process the PS services and configured with the GEPUG/GFGUG to provide the Gb interface. To determine the numbers of boards and Gb interface links, you need to obtain the following information:
The data transmission rate on the Um interface varies with the coding scheme. See Table 1.
Coding Scheme |
Transmission Rate (kbit/s) |
---|---|
CS-1 |
9.05 |
CS-2 |
13.4 |
CS-3 |
15.6 |
CS-4 |
21.4 |
MCS-1 |
8.8 |
MCS-2 |
11.2 |
MCS-3 |
14.8 |
MCS-4 |
17.6 |
MCS-5 |
22.4 |
MCS-6 |
29.6 |
MCS-7 |
44.8 |
MCS-8 |
54.4 |
MCS-9 |
59.2 |
The principles of configuring the GDPUP/GEPUG/GFGUG are as follows: