Configuring the Line Clock for the GMPS

The line clock of the BSC is provided by the MSC. When the BM and TC are configured in the same subrack, the GMPS extracts the line clock from the MSC through the A interface board. This line clock is used as the reference clock for the GMPS and the GEPS.

ScenarioBSC initial configuration and BSC capacity expansion
Mandatory/OptionalMandatory
NOTE:

If the GEIUA is configured in the GMPS, a maximum of two line clocks, line clock 0 and line clock 1, can be configured, and the line clock must be configured on the E1/T1 of the A interface. If the GOIUA is configured in the GMPS, only one line clock can be and must be configured on port 0 on the GOIUA.

Prerequisites

Preparation

NOTE:

The following procedure takes how to configure two line clocks on the GEIUA in the GMPS as an example.

Table 1 Example of the data negotiated and planned for configuring the clock on line 0 for the GMPS

Parameter

Example

Source

Line No.

LINE0

BSC internal planning

Line Clock Type

8K

BSC internal planning

Board Slot No.

18

BSC internal planning

Board Port No.

0

BSC internal planning

Backup Port No.

2

BSC internal planning

Table 2 Example of the data negotiated and planned for configuring the clock on line 1 for the GMPS

Parameter

Example

Source

Line No.

LINE1

BSC internal planning

Line Clock Type

8K

BSC internal planning

Board Slot No.

18

BSC internal planning

Board Port No.

1

BSC internal planning

Backup Port No.

3

BSC internal planning

Procedure

  1. On the BSC6000 Local Maintenance Terminal, right-click the edge of the GMPS.
  2. Choose Configure Line Clock from the shortcut menu. A dialog box is displayed, as shown in Figure 1.

    Figure 1 Configuring the clock on line 0

    NOTE:

    When the A interface E1 where the port of the selected Board Port No. is located incurs a fault, the GTCS cannot extract the line clock from the A interface. In this case, the GMPS can extract the line clock from the A interface through the A interface E1 where the port of the selected Backup Port No. is located.

    • Board Slot No.: number of the slot where the GEIUA/GOIUA configured with the A interface E1 is located
    • Board Port No.: number of the port connected to one A interface E1 on the GEIUA/GOIUA
    • Backup Port No.: number of the port connected to another A interface E1 on the GEIUA

  3. Set the parameters by referring to Table 1.
  4. Click Add. The clock on LINE0 for the GMPS is configured.
  5. Repeat 1 through 2 to open the configuration dialog box.
  6. Select LINE1 and set the parameters by referring to Table 2, as shown in Figure 2.

    Figure 2 Configuring the clock on line 1

  7. Click Add. The clock on LINE1 for the GMPS is configured.