Configuring the BSC Attributes

This describes how to configure BSC attributes. In the initial configuration of BSC attributes, you need to configure only the basic attributes. For other attributes, use the default settings. The BSC attributes include the Basic Data, Flow Control Data, BSC Timer, Software Parameters, User Resource Binding, SCCP, NSS and BSSGP, MSC Pool Parameters, Trigger Saving Power Function, IP Transfers, Abis Congestion Control, and Single Pass Exclude MSISDN Number.

ScenarioBSC initial configuration
Mandatory/OptionalMandatory

Prerequisite

The BSC attributes are determined in network planning.

Preparation

Table 1 Example of the data negotiated and planned for configuring BSC attributes with BM and TC combined

Parameter

Example

Source

BSC Name

BSC001

Network planning

Country Code

86

Network planning

City Code

021

Network planning

MCC

460

Network planning

MNC

10

Network planning

A Interface Tag

GSM_PHASE_2+

Network planning

Um Interface Tag

GSM_PHASE_2+

Network planning

Abis Interface Tag

GSM_PHASE_2+

Network planning

NTP Server

10.161.72.251

Negotiation with the M2000

BSC Subrack Combination Type

IP on A Interface

Network planning

Procedure

  1. On the BSC6000 Local Maintenance Terminal, right-click the BSC6000 root node.
  2. Choose Configure BSC Attributes from the shortcut menu. A dialog box is displayed, as shown in Figure 1.

    Figure 1 Configure BSC Attributes dialog box

  3. On the Basic Data tab page, set the parameters by referring to Table 1.

    NOTE:

    For other parameters, except the parameters listed in Table 1, you can use the default settings or change them as required.

  4. Click Finish. The configuration of the BSC attributes is complete.

Huawei Proprietary and Confidential