Configuring the BTS3012 S2/2/2

This describes how to configure the S2/2/2 for the BTS3012.

ScenarioBSC initial configuration and BSC capacity expansion
Mandatory/OptionalMandatory
NOTE:

The procedure for configuring the S2/2/2 for the BTS in TDM transmission mode is the same as that for configuring the S2/2/2 for the BTS in HDLC/HUB transmission mode.

Prerequisites

Preparation

Table 1 Example of the data negotiated and planned for configuring the BTS3012 S2/2/2

Parameter

Example

Source

Site Attributes dialog box

Site Name

BTS 1

Network planning

SiteType

BTS3012

Network planning

Upper-Level Port No.

GEIUB Port 0

Network planning

Multiplexing Mode

4:1

Network planning

FlexAbis Mode

Fix

Network planning

Service Mode

TDM

Network planning

Support Separate

Selected

Network planning

Active

Deselected

Network planning

Config Ring

No

Network planning

Config AbisByPass

No

Network planning

Cell attributes

Number of Cells

3

Network planning

Cell Name

Cell 1-0, cell 1-1, cell 1-2

Network planning

Frequency Band

GSM900

Network planning

MCC

460

Network planning

MNC

01

Network planning

LAC

8240

Network planning

CI

1, 2, 3

Network planning

BCC

1

Network planning

NCC

1

Network planning

Cell Extension Type

Common cell

Network planning

Cell Type

Common cell

Network planning

TRX Attributes

Assigned Cell

Cell 1-0, cell 1-1, cell 1-2

Network planning

Frequency configuration

98 (main BCCH frequency), 105

76 (main BCCH frequency), 103

115 (main BCCH frequency), 119

Network planning

TRX configuration

TRX 0, TRX 1

TRX2, TRX3

TRX4, TRX5

Network planning

FH Mode

None

Network planning

Antenna feeder attributes

Tributary No.

Downlink Tributary

Network planning

Frequency Band

PGSM900

Network planning

TRX Transmit and Receive Relationship

TRX No.1: 0, 0, A; TRX No.2: 0, 1, B

TRX No.1: 1, 0, A; TRX No.2: 1, 1, B

TRX No.1: 2, 0, A; TRX No.2: 2, 1, B

Network planning

Procedure

  1. Start the wizard for adding a BTS.

    • When adding a BTS for the first time, you can start the wizard for adding a BTS only on the GEIUB/GOIUB in the GMPS or GEPS. On the BSC6000 Local Maintenance Terminal, right-click a GEIUB in the GMPS.
    • If a BTS already exists, you can add a cascaded BTS under this BTS. On the Management Tree tab page, right-click a BTS.

  2. Choose Add Site. A dialog box is displayed, as shown in Figure 1.

    Figure 1 Add Site dialog box (1)

  3. Click Add Site. A dialog box is displayed, as shown in Figure 2.

    Figure 2 Add New Site dialog box

  4. Set the parameters by referring to Table 1.
  5. Click OK. A dialog box is displayed, as shown in Figure 3.

    Figure 3 Add Site dialog box (2)

  6. Click Next. A dialog box is displayed, as shown in Figure 4.

    Figure 4 Add Site dialog box (3)

  7. Select a BTS, and then click Add Cell. A dialog box is displayed, as shown in Figure 5.

    Figure 5 Adding a cell

  8. Set the parameters by referring to Table 1.

    NOTE:

    To add multiple cells at a time, set Number of Cells. The added cells are named in the format of current Cell Name + sequence number.

  9. Click OK. A dialog box is displayed, as shown in Figure 6.

    Figure 6 Add Site dialog box (4)

  10. Click Next. A dialog box is displayed, as shown in Figure 7.

    Figure 7 Add Site dialog box (5)

  11. Click Site Attributes. A dialog box is displayed, as shown in Figure 8.

    Figure 8 Site Device Attributes dialog box

  12. Configure S2 for cell 1-0.
    1. Right-click an idle slot holding subrack 1 and then choose Add Board > DTRU from the shortcut menu. A DTRU is added.
    2. Right-click the DTRU and then choose Binding logical TRX from the shortcut menu. A dialog box is displayed, as shown in Figure 9.

      Figure 9 Binding logical TRX dialog box

    3. Select two logical TRXs by referring to Table 1 and set Assigned Cell to Cell 1-0.
    4. Click OK. The logical TRX of the DTRU is configured.
    5. Right-click the DDPU and then choose Configure Board Attributes from the shortcut menu. A dialog box is displayed, as shown in Figure 10.

      Figure 10 Set Antenna Feeder Property dialog box

    6. Set the attribute parameters of the DDPU by referring to Table 1.
    7. Click Finish. The configuration of S2 for cell 1-0 is complete.
  13. Configure S2 for cell 1-1.
    1. Right-click an idle slot holding subrack 1 and then choose Add Board > DTRU from the shortcut menu. A DTRU is added.
    2. Right-click the DTRU and then choose Binding logical TRX from the shortcut menu. A dialog box is displayed, as shown in Figure 11.

      Figure 11 Binding logical TRX dialog box

    3. Select two logical TRXs by referring to Table 1 and set Assigned Cell to Cell 1-1.
    4. Click OK. The logical TRX of the DTRU is configured.
    5. Right-click the DDPU and then choose Configure Board Attributes from the shortcut menu. A dialog box is displayed, as shown in Figure 12.

      Figure 12 Set Antenna Feeder Property dialog box

    6. Set the attribute parameters of the DDPU by referring to Table 1.
    7. Click Finish. The configuration of S2 for cell 1-1 is complete.
  14. Configure S2 for cell 1-2.
    1. Right-click an idle slot holding subrack 1 and then choose Add Board > DTRU from the shortcut menu. A DTRU is added.
    2. Right-click the DTRU and then choose Binding logical TRX from the shortcut menu. A dialog box is displayed, as shown in Figure 13.

      Figure 13 Binding logical TRX dialog box

    3. Select two logical TRXs by referring to Table 1 and set Assigned Cell to Cell 1-2.
    4. Click OK. The logical TRX of the DTRU is configured.
    5. Right-click the DDPU and then choose Configure Board Attributes from the shortcut menu. A dialog box is displayed, as shown in Figure 14.

      Figure 14 Set Antenna Feeder Property dialog box

    6. Set the attribute parameters of the DDPU by referring to Table 1.
    7. Click Finish. The configuration of S2 for cell 12 is complete.
  15. Click Next. A dialog box is displayed, as shown in Figure 15.

    Figure 15 Add Site dialog box (6)

  16. Select the added cell, and then click Cell Attributes. A dialog box is displayed, as shown in Figure 16.

    Figure 16 Set Cell Attributes dialog box

  17. Set the basic attributes of cell 1-0, cell 1-1, and cell 1-2 in sequence by referring to Table 1.

    NOTE:
    • For two cells, the values of at least one of the following parameters should be different: MCC, MNC, LAC, and CI.
    • If you select GPRS Support, the BSC must be configured with the PCU. If the BTS does not support the GPRS function or the GPRS services are unavailable in the cell, do not select GPRS Support.
    • When you select EDGE Support, GPRS Support is selected automatically if the GPRS function is not enabled. You also need to select a PCU from the PCU drop-down list.

  18. Click OK to return to the dialog box, as shown in Figure 15.
  19. Click Finish. The configuration of the BTS3012 S2/2/2 is complete.
  20. Activating a BTS.
    1. On the Management Tree tab page of the BSC6000 Local Maintenance Terminal, right-click the target BTS and choose Site Operation > Set Site Active State from the shortcut menu. A dialog box is displayed, as shown in Figure 17.

      Figure 17 Set Site Active State dialog box

    2. Under Site Active State, select Activated. Then, click Finish to complete the BTS activation.

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.