This describes how to configure the S2/2/2 for the BTS3012.
Scenario | BSC initial configuration and BSC capacity expansion |
Mandatory/Optional | Mandatory |
The procedure for configuring the S2/2/2 for the BTS in TDM transmission mode is the same as that for configuring the S2/2/2 for the BTS in HDLC/HUB transmission mode.
Parameter |
Example |
Source |
|
---|---|---|---|
Site Attributes dialog box |
Site Name |
BTS 1 |
Network planning |
SiteType |
BTS3012 |
Network planning |
|
Upper-Level Port No. |
GEIUB Port 0 |
Network planning |
|
Multiplexing Mode |
4:1 |
Network planning |
|
FlexAbis Mode |
Fix |
Network planning |
|
Service Mode |
TDM |
Network planning |
|
Support Separate |
Selected |
Network planning |
|
Active |
Deselected |
Network planning |
|
Config Ring |
No |
Network planning |
|
Config AbisByPass |
No |
Network planning |
|
Cell attributes |
Number of Cells |
3 |
Network planning |
Cell Name |
Cell 1-0, cell 1-1, cell 1-2 |
Network planning |
|
Frequency Band |
GSM900 |
Network planning |
|
MCC |
460 |
Network planning |
|
MNC |
01 |
Network planning |
|
LAC |
8240 |
Network planning |
|
CI |
1, 2, 3 |
Network planning |
|
BCC |
1 |
Network planning |
|
NCC |
1 |
Network planning |
|
Cell Extension Type |
Common cell |
Network planning |
|
Cell Type |
Common cell |
Network planning |
|
TRX Attributes |
Assigned Cell |
Cell 1-0, cell 1-1, cell 1-2 |
Network planning |
Frequency configuration |
98 (main BCCH frequency), 105 76 (main BCCH frequency), 103 115 (main BCCH frequency), 119 |
Network planning |
|
TRX configuration |
TRX 0, TRX 1 TRX2, TRX3 TRX4, TRX5 |
Network planning |
|
FH Mode |
None |
Network planning |
|
Antenna feeder attributes |
Tributary No. |
Downlink Tributary |
Network planning |
Frequency Band |
PGSM900 |
Network planning |
|
TRX Transmit and Receive Relationship |
TRX No.1: 0, 0, A; TRX No.2: 0, 1, B TRX No.1: 1, 0, A; TRX No.2: 1, 1, B TRX No.1: 2, 0, A; TRX No.2: 2, 1, B |
Network planning |
To add multiple cells at a time, set Number of Cells. The added cells are named in the format of current Cell Name + sequence number.