This describes how to configure the 8 kHz clock provided by the GGCU as the 8 kHz reference clock for the GEPS. The 8 kHz reference clock serves as the synchronization clock for the boards in the GEPS.
| Scenario | BSC initial configuration and BSC capacity expansion | 
| Mandatory/Optional | Mandatory | 
  
Prerequisites
Preparation
Table 1 Example of the data negotiated and planned for configuring the 8 kHz reference clock for the GEPS
Parameter 
 | 
Example 
 | 
Source 
 | 
8K Reference Clock Type 
 | 
GGCU Backplane 
 | 
BSC internal planning 
 | 
 
  
Procedure
- On the BSC6000 Local Maintenance Terminal, right-click the edge of the GEPS.
 
- Choose  from the shortcut menu. A dialog box is displayed, as shown in Figure 1.
Figure 1 Configure GSCU 8K Reference Clock dialog box
 
 
- Set the parameters by referring to Table 1.
 
- Click Finish. The configuration of the 8 kHz reference clock for the GEPS is complete.
 
- Repeat 1 through 4 to configure the 8 kHz reference clock for multiple GEPSs.
 
 