The Port is the port number
of the E1 port for specifying the main control board. For the BTS3012
and BTS3012AE, each DTMU board has eight E1 ports with the port numbers
from 0 to 7. For BTSs of other types, each DTMU board has four E1
ports with port numbers from 0 to 3.
The Loop-back
Mode consists of E1 Loop-back or Timeslot Loop-back. When E1 Loop-back is selected, all the timeslots of the specified E1 port are tested.
The maximum testing duration is 60 minutes. The time unit is minute.
When Timeslot Loop-back is selected, only one
timeslot can be tested at a time. You need to specify the number of
timeslot to be tested. The maximum testing duration is 1440 minutes.
The time unit is 10 minutes.