An OM command that queries the running parameters of the boards such as DATU, DDPU, NFCB, DHEU, PTU, TRU, DTMU, GTMU, DRRU, UBFA, UPEU, UEIU, USCU, DRFU, FMU, FMUA, DTCU, GATM, DEMU, RXU, and BTS3900E.
1. The BTS should be configured with the corresponding board.
2. The communication between the MML and the BSC should be normal.
3. The BSC should communicate with the BTS properly.
ID | Name | Description |
---|---|---|
IDXTYPE | Index Type | Meaning: how to specify a BTS Value range: BYNAME(By Name), BYIDX(By Index) Explanation: This parameter determines whether to specify a BTS by its name or index. Default value: None |
BTSIDX | BTS Index | Meaning: BTS index Value range: 0-2047 Explanation: 1. This parameter specifies the number of a BTS. Each BTS is numbered uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYIDX(By Index). Default value: None |
BTSNAME | BTS Name | Meaning: BTS name Value range: 1-32 characters Explanation: 1. This parameter specifies the name of the target BTS. Each BTS is named uniquely in a BSC. 2. This parameter is mandatory if Index Type is set to BYNAME(By Name). Default value: None |
BRDTYPE | Board Type | Meaning: board type Value range: NORMAL(Normal Board), RXU(RXU Board) Explanation: The NORMAL parameter specifies the common boards, not including the RXU, and the RXU parameter specifies the RXU series boards. Default value: None |
SRN | Subrack No. | Meaning: subrack number Value range: 0-53 Explanation: This parameter specifies the number of the subrack where a BTS board is located. The subrack number is unique in a site. Default value: None |
SN | Slot No. | Meaning: slot number Value range: 0-23 Explanation: This parameter specifies the number of the slot in which a BTS board is located. Default value: None |
MODNO | Module No. | Meaning: module number Value range: 0-35 Desription: This parameter specifies the number of a branch of RET antenna. Default value: None |
RXUIDXTYPE | Index Type for RXU | Meaning: index type of the RXU Value range: RXUN(RXU No.), RXUNAME(RXU Name), RXUSRNSN(RXU Subrack No. and Slot No.) Explanation: RXUN(RXU No.) indicates the query based on the RXU No., the RXUNAME(RXU Name) determins the query based on the RXU name, and |
RXUN | RXU No. | Meaning: number of an RXU board Value range: 0-71 Explanation: This parameter specifies the number of an RXU board. Default value: None |
RXUNAME | RXU Name | Meaning: name of an RXU board Value range: 1-32 characters Explanation: This parameter specifies the name of an RXU board. Default value: None |
RXUSRN | Subrack No. | Meaning: subrack number Value range: 0-53 Explanation: This parameter specifies the number of the subrack where a BTS board is located. The subrack number is unique in a site. Default value: None |
RXUSN | Slot No. | Meaning: slot number Value range: 0-23 Explanation: This parameter specifies the number of the slot in which a BTS board is located. Default value: None |
Query the running parameters of the UBFA (Index Type = BYIDX(By Index); BTS Index = 0; Board Type = Normal; Subrack No. = 0; Slot No. = 1): DSP BTSBRDRP: IDXTYPE=BYIDX, BTSIDX=0, BRDTYPE=NORMAL, SRN=0, SN=1; The result is as follows: +++ HUAWEI 2008-06-24 11:24:50 O&M #13680 %%DSP BTSBRDRP: IDXTYPE=BYIDX, BTSIDX=0, BRDTYPE=NORMAL, SRN=0, SN=1;%% RETCODE = 0 Operation succeeded DSP BTSBRDRP Result ------------------- Site Name = DBS3900_GSM_7 Board type = UBFA Board No. = 0 Fan Speed Percent = 40% Temperature = 36.0Celsius (Number of results = 1) --- END