An OM command that queries the antenna parameters of the BTS.
To query the antenna parameters of a BTS, set the parameters such as BTS Index or BTS Name, Subrack No., and Slot No.
| ID | Name | Description |
|---|---|---|
| IDXTYPE | Index Type | Meaning:Index Type Value range:BYNAME(By Name),BYIDX(By Index) Explanation:Index type. Default value:None |
| BTSIDX | BTS Index | Meaning:BTS Index Value range:0~2047 Explanation:This parameter specifies the index number of a BTS. Each BTS is numbered uniquely in a BSC. Default value:None |
| BTSNAME | BTS Name | Meaning:BTS Name Value range:1-32 characters Explanation:This parameter specifies the name of a BTS. The name of each BTS is unique in a BSC. Excluding the invalid characters ';',',','"','''','=','\','%%','+++','&','#'. Default value:None |
| SRN | Subrack No. | Meaning:Subrack No. Value range:0~53 Explanation:This parameter specifies the unique number of the subrack where the board is located within each BTS in a BSC. Default value:None |
| SN | Slot No. | Meaning:Slot No. Value range:0~23 Explanation:This parameter specifies the number of the slot in which a BTS board is located. Default value:None |
Query parameters of the BTS antenna (Index Type = BYIDX(By Index); BTS Index = 1; Subrack No. = 3; Slot No. = 0):
LST ANTFEEDER: IDXTYPE=BYIDX, BTSIDX=1, SRN=3, SN=0;
The result is as follows:
+++ HUAWEI 2008-07-22 17:28:45
O&M #6624
%%LST ANTFEEDER: IDXTYPE=BYIDX, BTSIDX=1, SRN=3, SN=0;%%
RETCODE = 0 Operation succeeded
LST ANTFEEDER Result
--------------------
Board Type = DDPU/DDPM
Uplink Tributary 0 TRX Board 1 = 0
Uplink Tributary 0 TRX Board Pass 1 = 255
Uplink Tributary 0 TRX Board 2 = 255
Uplink Tributary 0 TRX Board Pass 2 = 255
Uplink Tributary 0 TRX Board 3 = 255
Uplink Tributary 0 TRX Board Pass 3 = 255
Uplink Tributary 0 TRX Board 4 = 255
Uplink Tributary 0 TRX Board Pass 4 = 255
Uplink Tributary 0 TRX Board 5 = 255
Uplink Tributary 0 TRX Board Pass 5 = 255
Uplink Tributary 0 TRX Board 6 = 255
Uplink Tributary 0 TRX Board Pass 6 = 255
Uplink Tributary 0 TRX Board 7 = 255
Uplink Tributary 0 TRX Board Pass 7 = 255
Uplink Tributary 0 TRX Board 8 = 255
Uplink Tributary 0 TRX Board Pass 8 = 255
Uplink Tributary 0 TRX Board 9 = 255
Uplink Tributary 0 TRX Board Pass 9 = 255
Uplink Tributary 0 TRX Board 10 = 255
Uplink Tributary 0 TRX Board Pass 10 = 255
Uplink Tributary 0 TRX Board 11 = 255
Uplink Tributary 0 TRX Board Pass 11 = 255
Uplink Tributary 0 TRX Board 12 = 255
Uplink Tributary 0 TRX Board Pass 12 = 255
Uplink Tributary 0 Amplifier Flag = No
Uplink Tributary 0 Power Attenuation Factor = 0
Uplink Tributary 1 TRX Board 1 = 0
Uplink Tributary 1 TRX Board Pass 1 = 255
Uplink Tributary 1 TRX Board 2 = 255
Uplink Tributary 1 TRX Board Pass 2 = 255
Uplink Tributary 1 TRX Board 3 = 255
Uplink Tributary 1 TRX Board Pass 3 = 255
Uplink Tributary 1 TRX Board 4 = 255
Uplink Tributary 1 TRX Board Pass 4 = 255
Uplink Tributary 1 TRX Board 5 = 255
Uplink Tributary 1 TRX Board Pass 5 = 255
Uplink Tributary 1 TRX Board 6 = 255
Uplink Tributary 1 TRX Board Pass 6 = 255
Uplink Tributary 1 TRX Board 7 = 255
Uplink Tributary 1 TRX Board Pass 7 = 255
Uplink Tributary 1 TRX Board 8 = 255
Uplink Tributary 1 TRX Board Pass 8 = 255
Uplink Tributary 1 TRX Board 9 = 255
Uplink Tributary 1 TRX Board Pass 9 = 255
Uplink Tributary 1 TRX Board 10 = 255
Uplink Tributary 1 TRX Board Pass 10 = 255
Uplink Tributary 1 TRX Board 11 = 255
Uplink Tributary 1 TRX Board Pass 11 = 255
Uplink Tributary 1 TRX Board 12 = 255
Uplink Tributary 1 TRX Board Pass 12 = 255
Uplink Tributary 1 Amplifier Flag = No
Uplink Tributary 1 Power Attenuation Factor = 0
Downlink Tributary TRX Board 1 = 0
Downlink Tributary TRX Board Pass 1 = 255
Downlink Tributary TRX No.1 MDU No. = A
Downlink Tributary TRX Board 2 = 255
Downlink Tributary TRX Board Pass 2 = 255
Downlink Tributary TRX No.2 MDU No. = NULL
Downlink Tributary TRX Board 3 = 255
Downlink Tributary TRX Board Pass 3 = 255
Downlink Tributary TRX No.3 MDU No. = NULL
Downlink Tributary TRX Board 4 = 255
Downlink Tributary TRX Board Pass 4 = 255
Downlink Tributary TRX No.4 MDU No. = NULL
Downlink Tributary TRX Board 5 = 255
Downlink Tributary TRX Board Pass 5 = 255
Downlink Tributary TRX No.5 MDU No. = NULL
Downlink Tributary TRX Board 6 = 255
Downlink Tributary TRX Board Pass 6 = 255
Downlink Tributary TRX No.6 MDU No. = NULL
Downlink Tributary TRX Board 7 = 255
Downlink Tributary TRX Board Pass 7 = 255
Downlink Tributary TRX No.7 MDU No. = NULL
Downlink Tributary TRX Board 8 = 255
Downlink Tributary TRX Board Pass 8 = 255
Downlink Tributary TRX No.8 MDU No. = NULL
Downlink Tributary TRX Board 9 = 255
Downlink Tributary TRX Board Pass 9 = 255
Downlink Tributary TRX No.9 MDU No. = NULL
Downlink Tributary TRX Board 10 = 255
Downlink Tributary TRX Board Pass 10 = 255
Downlink Tributary TRX No.10 MDU No. = NULL
Downlink Tributary TRX Board 11 = 255
Downlink Tributary TRX Board Pass 11 = 255
Downlink Tributary TRX No.11 MDU No. = NULL
Downlink Tributary TRX Board 12 = 255
Downlink Tributary TRX Board Pass 12 = 255
Downlink Tributary TRX No.12 MDU No. = NULL
Freq. Band Type = PGSM900
(Number of results = 1)
--- END