Modify Antenna Feeder Board of BTS(MOD ANTFEEDER)

Function

A configuration command that modifies the parameters related to the antenna feeder board of the BTS. In this command, the following parameters uniquely identify the board:

BTS Index/BTS Name

Subrack No.

Slot No.

Board Type

Note

The specified antenna feeder board must be configured.

Parameters

ID Name Description
IDXTYPE Index Type

Meaning:Index Type

Value range:BYNAME(By Name),BYIDX(By Index)

Explanation:Index type.

Default value:None

BTSIDX BTS Index

Meaning:BTS Index

Value range:0~2047

Explanation:This parameter specifies the index number of a BTS. Each BTS is numbered uniquely in a BSC.

Default value:None

BTSNAME BTS Name

Meaning:BTS Name

Value range:1-32 characters

Explanation:This parameter specifies the name of a BTS. The name of each BTS is unique in a BSC. Excluding the invalid characters ';',',','"','''','=','\','%%','+++','&','#'.

Default value:None

SRN Subrack No.

Meaning:Subrack No.

Value range:0~53

Explanation:This parameter specifies the unique number of the subrack where the board is located within each BTS in a BSC.

Default value:None

SN Slot No.

Meaning:Slot No.

Value range:0~23

Explanation:This parameter specifies the number of the slot in which a BTS board is located.

Default value:None

BT Board Type

Meaning:Board Type

Value range:CDU(CDU),CDUC(CDUC),CDUP(CDUP),CDUR(CDUR),CDUE(CDUE),PCDU(PCDU),RCDU(RCDU),DCDU(DCDU),EDU(EDU),EDUC(EDUC),EDUP(EDUP),EDUR(EDUR),EDUE(EDUE),PEDU(PEDU),REDU(REDU),DEDU(DEDU),DDPM_DDPU(DDPM_DDPU),DFCU(DFCU),DFCB(DFCB)

Explanation:This parameter is used to differentiate boards with unique identifiers in the BTS.

Default value:None

DTRX1 Down TRX1 No.

Meaning:Down TRX1 No.

Value range:1(1),2(2),3(3),4(4),5(5),6(6),7(7),8(8),9(9),10(10),11(11),12(12)

Explanation:Down TRX No.

Default value:None

DTRX2 Down TRX2 No.

Meaning:Down TRX2 No.

Value range:1(1),2(2),3(3),4(4),5(5),6(6),7(7),8(8),9(9),10(10),11(11),12(12)

Explanation:Down TRX No.

Default value:None

DTRX3 Down TRX3 No.

Meaning:Down TRX3 No.

Value range:1(1),2(2),3(3),4(4),5(5),6(6),7(7),8(8),9(9),10(10),11(11),12(12)

Explanation:Down TRX No.

Default value:None

DTRXBN1 Down TRX Board No.

Meaning:Down TRX Board No.

Value range:0~71,255

Explanation:This parameter specifies the unique number of each board type in a site.

Default value:None

DTRXPS1 Down TRX Board Pass No.

Meaning:Down TRX Board Pass No.

Value range:0~1

Explanation:Number of a TRX on uplink tributary 0

Value 255 indicates that no TRX is connected.

Default value:None

DTRXBN2 Down TRX Board No.

Meaning:Down TRX Board No.

Value range:0~71,255

Explanation:This parameter specifies the unique number of each board type in a site.

Default value:None

DTRXPS2 Down TRX Board Pass No.

Meaning:Down TRX Board Pass No.

Value range:0~1

Explanation:Number of a TRX on uplink tributary 0

Value 255 indicates that no TRX is connected.

Default value:None

DTRXBN3 Down TRX Board No.

Meaning:Down TRX Board No.

Value range:0~71,255

Explanation:This parameter specifies the unique number of each board type in a site.

Default value:None

DTRXPS3 Down TRX Board Pass No.

Meaning:Down TRX Board Pass No.

Value range:0~1

Explanation:Number of a TRX on uplink tributary 0

Value 255 indicates that no TRX is connected.

Default value:None

AORB1 Down TRX1 A OR B

Meaning:Down TRX1 A OR B

Value range:A(A),B(B),NULL(NULL)

Explanation:Downlink Tributary Antenna Feeder Pass No.

Default value:None

AORB2 Down TRX2 A OR B

Meaning:Down TRX2 A OR B

Value range:A(A),B(B),NULL(NULL)

Explanation:Downlink Tributary Antenna Feeder Pass No.

Default value:None

DMDUA Down MDU A

Meaning:Down MDU A

Value range:0~255

Explanation:This parameter specifies the number of the MDU connected to channel A on the EDU, DDPU, or DDPM. 255 indicates that no link is established to the MDU.

Default value:None

DMDUB Down MDU B

Meaning:Down MDU B

Value range:0~255

Explanation:This parameter specifies the number of the MDU connected to channel B on the EDU, DDPU, or DDPM. 255 indicates that no link is established to the MDU.

Default value:None

UNO Up No.

Meaning:Up No.

Value range:0(0),1(1)

Explanation:Up No.

Default value:None

UTRX Up TRX No.

Meaning:Up TRX No.

Value range:1(1),2(2),3(3),4(4),5(5),6(6),7(7),8(8),9(9),10(10),11(11),12(12)

Explanation:Up TRX No.

Default value:None

UTRXBN Up TRX Board No.

Meaning:Up TRX Board No.

Value range:0~71,255

Explanation:Uplink Tributary TRX Board No.

Default value:None

UTRXBPN Up TRX Board Pass No.

Meaning:Up TRX Board Pass No.

Value range:0~1

Explanation:Uplink Tributary TRX Pass No.

Default value:None

UTOW Up Tower-Top Amplifier Flag

Meaning:Up Tower-Top Amplifier Flag

Value range:NO(NO),YES(YES)

Explanation:Up Tower.

Default value:None

UGEN Up Power Attenuation Factor

Meaning:Up Power Attenuation Factor

Value range:0~15

Explanation:Up Gene.

Default value:None

NEWBT1 New Board Type1

Meaning:New Board Type1

Value range:CDU(CDU),CDUC(CDUC),CDUP(CDUP),CDUR(CDUR),CDUE(CDUE),PCDU(PCDU),RCDU(RCDU),DCDU(DCDU)

Explanation:New Board Type.

Default value:None

NEWBT2 New Board Type2

Meaning:New Board Type2

Value range:EDU(EDU),EDUC(EDUC),EDUP(EDUP),EDUR(EDUR),EDUE(EDUE),PEDU(PEDU),REDU(REDU),DEDU(DEDU)

Explanation:New Board Type.

Default value:None

ANTFREQBAND Frequency Band Attribute of Antenna

Meaning:Frequency Band Attribute of Antenna

Value range:PGSM900(PGSM900),EGSML25(EGSM<L25>),EGSM35M(EGSM<35M>),RGSML25(RGSM<L25>),GSM900_RGSM39M(GSM900_RGSM<39M>),DCS1800(DCS1800),PCS1900(PCS1900),GSM850(GSM850),EGSM24M(EGSM<24M>),DCS1800_L(DCS1800<L50M>),DCS1800_H(DCS1800<H50M>)

Explanation:This parameter specifies the frequency band types. This parameter is only applicable to the DDPU/DFCU/DFCB/DCOM/DDPM/DCBM.

The frequency band types for the DTRU, QTRU, DRRU, DRFU, GRRU, MRRU, GRFU, and MRFU cannot be configured and thus are calculated based on the selected frequencies such as GSM900, DSC1800, PCS1900,and GSM850.

The parameter value for the other board types is set to 0xFF.

Default value:None

Example

Modify the parameters of an antenna feeder (Index Type = BYIDX(By Index); BTS Index = 3; Subrack No. = 3; Slot No. = 0; Board Type = DDPM_DDPU(DDPM_DDPU); Down TRX3 No. = 4; Down TRX Board No. = 32; Up No. = 0):
MOD ANTFEEDER: IDXTYPE=BYIDX, BTSIDX=3, SRN=3, SN=0, BT=DDPM_DDPU, DTRX3=4, DTRXBN3=32, UNO=0;
Related reference
Add Antenna Feeder Board of BTS(ADD ANTFEEDER)
Add BTS Board(ADD BTSBRD)

Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.