An OM command that queries the software parameters of a cell.
To query the software parameters of all cells under the BSC, do not set any parameter.
To query the software parameters of all cells under a BTS, set BTS Index or BTS Name.
To query the software parameters of a specific cell, set Cell Index or Cell Name.
ID | Name | Description |
---|---|---|
IDXTYPE | Index Type | Meaning:Index Type Value range:BYNAME(By Name),BYIDX(By Index) Explanation: Index Type. Default value:None |
BTSIDX | BTS Index | Meaning:BTS Index Value range:0~2047 Explanation: This parameter specifies the index number of a BTS. Each BTS is numbered uniquely in a BSC. Default value:None |
BTSNAME | BTS Name | Meaning:BTS Name Value range:1-32 characters Explanation: This parameter specifies the name of a BTS. The name of each BTS is unique in a BSC. Excluding the invalid characters ';',',','"','''','=','\','%%','+++','&','#'. Default value:None |
CELLIDX | Cell Index | Meaning:Cell Index Value range:0~2047 Explanation: This parameter indicates the cell index. The cell index must be unique. Default value:None |
CELLNAME | Cell Name | Meaning:Cell Name Value range:1-32 characters Explanation: This parameter indicates the cell name. The name of each cell must be unique in one BSC. Default value:None |
1. To query software parameters of all cells under the BSC, run the LST CELLSOFT command directly: LST CELLSOFT:; The result is as follows: +++ HUAWEI 2008-12-10 22:52:45 O&M #8523 %%LST CELLSOFT:;%% RETCODE = 0 Operation succeeded LST CELLSOFT Result ------------------- Cell Index Cell Name Aiding Delay Protect Time(min) Directly Magnifier Site Flag Drop Optimize Error Indication (T200 timeout) Drop Optimize Error Indication (unsolicited DM response) Drop Optimize Error Indication (sequence error) Drop Optimize Connection Failure (radio link fail) Drop Optimize Connection Failure (HO access fail) Drop Optimize Connection Failure (OM intervention) Drop Optimize Connection Failure (radio resource not available) Drop Optimize Connection Failure (other) Drop Optimize Release Indication Drop Optimize ABIS Territorial Link Failure Drop Optimize Equipment Failure Drop Optimize Forced Handover Failure Drop Optimize No MR For Long Time Drop Optimize Resource Check Drop Optimize Into-Bsc Handover Timeout Drop Optimize Out-Bsc Handover Timeout Drop Optimize Intra-Bsc Out-Cell Handover Timeout Drop Optimize Intra-Cell Handover Timeout Frequence Scan Result Type IntraCellHo to Ass SWITCH Force MS to Send Ho Access SWITCH Sublink resources preemption switch Lower-level sublink resources preemption switch Cell Out-of-Service Alarm Switch Interfere Band Stat Algorithm Type Paging Messages Optimize at Abis Interface Interval For Sending Paging Optimizing Messages Paging Numbers of one Optimizing Msgs MS Capability Statistic Switch SD Quick Ho Cell EFR Forced Switch Average Paging Message Number 0f Cell In Period MAX Paging Message Number 0f Cell In Period STIRC Allowed Enquire Classmark After In-BSC Handover Enable Send Classmark Enquiring Result To MSC Enable TCH Time Handover Switch TCH Time Handover Period Flex TSC Switch Dummy Bit Randomization Switch Stop Transmit System Information 5/5bis/5ter Switch Activate L2 Re-establishment Bad Quality Disconnection Threshold Timer for Bad Quality Disconnection Statistic Report Downlink VQI Allowed Co-Cell Switch Location Group Power Switch FER Report Enable PDCH Power Saving Enable Switch for BTS Supporting SAIC Power Control Adjustment TSC Plan Enable Frequency Hoping Coding Scheme MAX TA Drop Call Switch MAX TA Drop Call Filter[0.5s] MAX TA Drop Call Threshold[bit] BTS Paging Lifetime 0 cell1 15 NO 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Maximum/Mean Value NO YES NO NO YES Interference Band Measurement Algorithm II Forced turn-on 2 5 OFF OFF NO 180 220 NO NO NO OFF 60 OFF OFF OFF NO 55 3 Disable YES 0 NO NO ON YES CA+MA OFF 20 255 255 1 cell2 15 NO 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Maximum/Mean Value NO YES NO NO YES Interference Band Measurement Algorithm II Forced turn-on 2 5 OFF OFF NO 180 220 NO NO NO OFF 60 OFF OFF OFF NO 55 3 Disable NO 0 NO NO ON YES CA+MA OFF 20 255 255 (Number of results = 2) --- END 2. Query the software parameters of a specific cell (Index Type = BYIDX(By Index); BTS Index = 0; Cell Index = 0): LST CELLSOFT: IDXTYPE=BYIDX, BTSIDX=0, CELLIDX=0; The result is as follows: +++ HUAWEI 2008-12-10 22:53:24 O&M #8532 %%LST CELLSOFT: IDXTYPE=BYIDX, BTSIDX=0, CELLIDX=0;%% RETCODE = 0 Operation succeeded LST CELLSOFT Result ------------------- Cell Index = 0 Cell Name = cell1 Aiding Delay Protect Time(min) = 15 Directly Magnifier Site Flag = NO Drop Optimize Error Indication (T200 timeout) = 1 Drop Optimize Error Indication (unsolicited DM response) = 1 Drop Optimize Error Indication (sequence error) = 1 Drop Optimize Connection Failure (radio link fail) = 1 Drop Optimize Connection Failure (HO access fail) = 1 Drop Optimize Connection Failure (OM intervention) = 1 Drop Optimize Connection Failure (radio resource not available) = 1 Drop Optimize Connection Failure (other) = 1 Drop Optimize Release Indication = 1 Drop Optimize ABIS Territorial Link Failure = 1 Drop Optimize Equipment Failure = 1 Drop Optimize Forced Handover Failure = 1 Drop Optimize No MR For Long Time = 1 Drop Optimize Resource Check = 1 Drop Optimize Into-Bsc Handover Timeout = 1 Drop Optimize Out-Bsc Handover Timeout = 1 Drop Optimize Intra-Bsc Out-Cell Handover Timeout = 1 Drop Optimize Intra-Cell Handover Timeout = 1 Frequence Scan Result Type = Maximum/Mean Value IntraCellHo to Ass SWITCH = NO Force MS to Send Ho Access SWITCH = YES Sublink resources preemption switch = NO Lower-level sublink resources preemption switch = NO Cell Out-of-Service Alarm Switch = YES Interfere Band Stat Algorithm Type = Interference Band Measurement Algorithm II Paging Messages Optimize at Abis Interface = Forced turn-on Interval For Sending Paging Optimizing Messages = 2 Paging Numbers of one Optimizing Msgs = 5 MS Capability Statistic Switch = OFF SD Quick Ho = OFF Cell EFR Forced Switch = NO Average Paging Message Number 0f Cell In Period = 180 MAX Paging Message Number 0f Cell In Period = 220 STIRC Allowed = NO Enquire Classmark After In-BSC Handover Enable = NO Send Classmark Enquiring Result To MSC Enable = NO TCH Time Handover Switch = OFF TCH Time Handover Period = 60 Flex TSC Switch = OFF Dummy Bit Randomization Switch = OFF Stop Transmit System Information 5/5bis/5ter Switch = OFF Activate L2 Re-establishment = NO Bad Quality Disconnection Threshold = 55 Timer for Bad Quality Disconnection Statistic = 3 Report Downlink VQI Allowed = Disable Co-Cell Switch = NO Location Group Power Switch = 0 FER Report Enable = NO PDCH Power Saving Enable = NO Switch for BTS Supporting SAIC Power Control Adjustment = ON TSC Plan Enable = YES Frequency Hoping Coding Scheme = CA+MA MAX TA Drop Call Switch = OFF MAX TA Drop Call Filter[0.5s] = 20 MAX TA Drop Call Threshold[bit] = 255 BTS Paging Lifetime = 255 (Number of results = 1) --- END