A configuration command that modifies the quick handover parameters of the cell. In this command, Cell Index or Cell Name uniquely identifies a cell.
ID | Name | Description |
---|---|---|
IDXTYPE | Index Type | Meaning:Index Type Value range:BYNAME(By Name),BYIDX(By Index) Explanation:Index Type. Default value:None |
CELLIDX | Cell Index | Meaning:Cell Index Value range:0~2047 Explanation: This parameter indicates the cell number, which is unique in a BSC. Default value:None |
CELLNAME | Cell Name | Meaning:Cell Name Value range:1-32 characters Explanation: This parameter indicates the name of a cell. The value ranges from 1 to 32 characters. Default value:None |
HOUPTRIGE | Quick handover up trigger level[db] | Meaning:Quick handover up trigger level[db] Value range:0~63 Explanation:During a measurement period, if the filtered uplink level of the serving cell is smaller than the value of this parameter, a quick handover is triggered. The level values 0 through 63 map to -110 dBm to -47 dBm. Default value:None |
HODOWNTRIGE | Quick handover down trigger level[db] | Meaning:Quick handover down trigger level[db] Value range:0~63 Explanation:During a measurement period, if the compensated downlink level of the serving cell is smaller than the value of this parameter, a quick handover is triggered. The level values 0 through 63 map to -110 dBm to -47 dBm. Default value:None |
MOVESPEEDTHRES | Quick move speed threshold[m/s] | Meaning:Quick move speed threshold[m/s] Value range:0~600 Explanation:During a measurement period, if the MS moves at a speed greater than the value of this parameter, a quick handover is triggered. Default value:None |
HOSTATICTIME | Quick handover static time[0.5s] | Meaning:Quick handover static time[0.5s] Value range:1~32 Explanation:The quick handover must comply with the P/N criterion. That is, the triggering conditions of quick handover must be met for N consecutive seconds within P seconds. This parameter corresponds to P of the P/N criterion. That is, if the triggering conditions of quick handover is met for a period longer than or equal to the value of this parameter, a quick handover is triggered. Default value:None |
HOLASTTIME | Quick handover last time[0.5s] | Meaning:Quick handover last time[0.5s] Value range:1~32 Explanation:The quick handover must comply with the P/N criterion. That is, the triggering conditions of quick handover must be met for N consecutive seconds within P seconds. This parameter corresponds to N of the P/N criterion, that is, the period during which the triggering conditions of quick handover are met. Such a period is within the value defined by this parameter. Default value:None |
SCELLFILTER | Serving cell filter length mr number | Meaning:Serving cell filter length mr number Value range:1~20 Explanation:This parameter specifies the number of measurement reports used for filtering after the BSC receives the measurement reports of the serving cell from the BTS. This helps to avoid improper handover decision based on a single inaccurate measurement report. Default value:None |
NCELLFILTER | Neighbor cell filter length mr number | Meaning:Neighbor cell filter length mr number Value range:1~20 Explanation:This parameter specifies the number of measurement reports used for filtering after the BSC receives the measurement reports of the adjacent cell from the BTS. This helps to avoid improper handover decision based on a single inaccurate measurement report. Default value:None |
IGNOREMRNUM | Ignore measurement report number | Meaning:Ignore measurement report number Value range:0~32 Explanation:This parameter specifies the allowed number of invalid measurement reports when the BSC uses the measurement reports for filtering. If the number of received measurement reports is smaller than or equal to the value of this parameter, no filtering is performed and no quick handover decision is made. Default value:None |
TIMEPUNISH | Quick handover punish time[s] | Meaning:Quick handover punish time[s] Value range:0~255 Explanation:This parameter specifies the duration of penalty that is imposed on the originating cell after a successful quick handover. Default value:None |
HOPUNISHVALUE | Quick handover punish value[db] | Meaning:Quick handover punish value[db] Value range:0~63 Explanation:This parameter specifies the penalty that is imposed on the downlink level of the originating cell after a successful quick handover. Default value:None |
HOOFFSET | Quick handover offset[db] | Meaning:Quick handover offset[db] Value range:0~127 Explanation:During a measurement period, a quick handover can be triggered only if the difference of path loss between a chain adjacent cell and the serving cell is greater than or equal to the value of this parameter. The level values 0 to 127 map to -64 dB to 63 dB. Default value:None |
MSLEVSTRQPBGT | Enable Quick PBGT HO Algorithm When MS Leaves BTS | Meaning:Enable Quick PBGT HO Algorithm When MS Leaves BTS Value range:NO(NO),YES(YES) Explanation: This parameter specifies whether to enable the quick PBGT algorithm when an MS leaves the BTS. Default value:None |